Preliminary Investigation of the Dissolution Behavior, Cytocompatibility, Effects of Fibrinogen Conformation and Platelet Adhesion for Radiopaque Embolic Particles
Open Access
- 10 July 2013
- journal article
- research article
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 4 (3) , 89-113
Abstract
Experimental embolic particles based on a novel zinc-silicate glass system have been biologically evaluated for potential consideration in transcatheter arterial embolization procedures. In addition to controlling the cytotoxicity and haemocompatibility for such embolic particles, its glass structure may mediate specific responses via dissolution in the physiological environment. In a 120 h in-vitro dissolution study, ion release levels for silicon (Si4+), sodium (Na+), calcium (Ca2+), zinc (Zn2+), titanium (Ti4+), lanthanum (La3+), strontium (Sr2+), and magnesium (Mg2+), were found to range from 0.04 to 5.41 ppm, 0.27–2.28 ppm, 2.32–8.47 ppm, 0.16–0.20 ppm, 0.12–2.15 ppm, 0.16–0.49 ppm and 0.01–0.12 ppm, respectively for the series of glass compositions evaluated. Initial release of Zn2+ (1.93–10.40 ppm) was only evident after 120 h. All compositions showed levels of cell viabilities ranging from 61.31 ± 4.33% to 153.7 ± 1.25% at 25%–100% serial extract dilutions. The conformational state of fibrinogen, known to induce thrombi, indicated that no changes were induced with respect of the materials dissolution by-products. Furthermore, the best-in-class experimental composition showed equivalency to contour PVA in terms of inducing platelet adhesion. The data generated here provides requisite evidence to continue to in-vivo pre-clinical evaluation using the best-in-class experimental composition evaluated.Keywords
All Related Versions
This publication has 58 references indexed in Scilit:
- Mixture designs to assess composition–structure–property relationships in SiO2–CaO–ZnO–La2O3–TiO2–MgO–SrO–Na2O glasses: Potential materials for embolizationJournal of Biomaterials Applications, 2012
- Development of “Imageable” Beads for Transcatheter EmbolotherapyJournal of Vascular and Interventional Radiology, 2010
- Embolization Agents—Which One Should Be Used When? Part 2: Small-Vessel EmbolizationSeminars in Interventional Radiology, 2010
- The relationship between platelet adhesion on surfaces and the structure versus the amount of adsorbed fibrinogenBiomaterials, 2010
- Prospective Randomized Study of Doxorubicin-Eluting-Bead Embolization in the Treatment of Hepatocellular Carcinoma: Results of the PRECISION V StudyCardioVascular and Interventional Radiology, 2009
- Porous silicon in drug delivery devices and materials☆Advanced Drug Delivery Reviews, 2008
- Serum Titanium Levels in Individuals Undergoing Intramedullary Femoral Nailing With a Titanium ImplantJournal of Trauma: Injury, Infection & Critical Care, 2008
- Thermal properties and devitrification behavior of (2.5−x)CaO·x/3La2O3·2SiO2Thermochimica Acta, 2000
- Barium sulphate-loaded p(HEMA) microspheres as artificial emboli: Preparation and propertiesBiomaterials, 1990
- Reversible middle cerebral artery embolization in dogs without intracranial surgery.Stroke, 1989