Cannulated Screw Fixation of Jones Fractures
Authors:
- 1 October 2004
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 32 (7) , 1736-1742
Abstract
Background: Traditional nonsurgical treatment of Jones fractures has high rates of delayed union, nonunion, and refracture. Internal fixation has become the treatment of choice in athletes and active patients. Purpose: The purpose of this study was (1) to review the short- and long-term clinical results of cannulated screw fixation of Jones fractures and (2) to perform a biomechanical evaluation of fatigue failure characteristics of several types of screws used in the fixation of Jones fractures. Study Design: Retrospective case series and in vitro biomechanical study. Methods: Ten male and 5 female patients with Jones fractures fixed with cannulated screws ranging from 4 mm to 6.5 mm in diameter were evaluated by chart review, review of radiographs, and telephone interview. Mean follow-up from surgery to phone survey was 34 months. Screws ranging in size from 2.7 mm to 7.3 mm, both cannulated and noncannulated, stainless steel and titanium, were tested in the laboratory by cyclic loading to 250 N up to a maximum of 200 000 cycles. Results: Mean time to healing as shown on radiographs and by full activity after surgery were 7.3 and 7.9 weeks, respectively. All patients were able to return to their previous levels of activity. Screw fatigue data showed that the number of cycles to failure increased with increasing screw diameter. For 4-mm screws, mean number of cycles to failure was 4308 for cannulated titanium screws, 22 012 for cannulated stainless steel screws, and 44 523 for noncannulated stainless steel screws. Conclusions: In our patients, cannulated screw fixation of Jones fractures was a procedure that was reliable, had low morbidity, and afforded athletes a quick return to activity. Clinical Relevance: The laboratory study suggests that the largest screw possible should be used for surgical fixation of these fractures and that screws less than 4 mm in diameter should be used with caution.Keywords
This publication has 11 references indexed in Scilit:
- FRACTURES OF THE BASE OF THE FIFTH METATARSALOrthopedic Clinics of North America, 2001
- Refracture of Proximal Fifth Metatarsal (Jones) Fracture After Intramedullary Screw Fixation in AthletesThe American Journal of Sports Medicine, 2000
- Intramedullary Screw Fixation of Jones Fractures: A Biomechanical StudyFoot & Ankle International, 1999
- Analysis of Failed Surgical Management of Fractures of the Base of the Fifth Metatarsal Distal to the Tuberosity: The Jones FractureFoot & Ankle International, 1996
- Clinical Rating Systems for the Ankle-Hindfoot, Midfoot, Hallux, and Lesser ToesFoot & Ankle International, 1994
- Jones Fracture Surgical Versus Nonsurgical TreatmentClinical Orthopaedics and Related Research, 1994
- Outpatient percutaneous screw fixation of the acute Jones fractureThe American Journal of Sports Medicine, 1993
- Stress fracture of the fifth metatarsalThe American Journal of Sports Medicine, 1983
- Proximal diaphyseal fractures of the fifth metatarsal —treatment of the fractures and their complications in athletesThe American Journal of Sports Medicine, 1979
- The Jones fracture revisited.Journal of Bone and Joint Surgery, 1978