Sensitivity encoding as a means of enhancing the SNR efficiency in steady‐state MRI
Open Access
- 22 December 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (1) , 177-185
Abstract
Sensitivity encoding (SENSE) with a receiver coil array is typically used as a means of reducing the scan time in MRI. The speed benefit usually comes at some expense in terms of the signal-to-noise ratio (SNR) efficiency, which has been notorious as the main downside of SENSE and parallel MRI in general. In this work it is shown that in steady-state gradient-echo imaging the parallel approach may as well be used to increase the SNR efficiency. The basic idea is to balance reduced phase encoding by increasing the repetition time. In this fashion both the acquisition duty cycle and the steady-state magnetization can be enhanced, resulting in considerable net gains in SNR yield. It is argued that the reduction factor in parallel imaging is essentially an additional degree of freedom in optimizing the SNR. The optimal SENSE factor depends on scan, tissue, and hardware parameters, assuming values up to 3.0 and higher. The achievable SNR benefit also depends on the spoiling regime and is most pronounced for RF-spoiled techniques. The proposed mechanism is demonstrated by simulations and phantom experiments, as well as by contrast-enhanced angiography in vivo, achieving an approximate doubling of the SNR efficiency. Magn Reson Med 53:177–185, 2005.Keywords
This publication has 15 references indexed in Scilit:
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Contrast-enhanced 3D MRA using SENSEJournal of Magnetic Resonance Imaging, 2000
- Contrast-enhanced 3D MR Angiography with Simultaneous Acquisition of Spatial Harmonics: A Pilot StudyRadiology, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993
- Spoiling of transverse magnetization in steady‐state sequencesMagnetic Resonance in Medicine, 1991
- Elimination of transverse coherences in FLASH MRIMagnetic Resonance in Medicine, 1988
- Transverse coherence in rapid FLASH NMR imagingJournal of Magnetic Resonance (1969), 1987
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986