Blood pressure monitoring during arrhythmia: agreement between automated brachial cuff and intra-arterial measurements
Open Access
- 14 September 2015
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 115 (4) , 540-549
Abstract
Since arrhythmia induces irregular pulse waves, it is widely considered to cause flawed oscillometric brachial cuff measurements of blood pressure (BP). However, strong data are lacking. We assessed whether the agreement of oscillometric measurements with intra-arterial measurements is worse during arrhythmia than during regular rhythm. Among patients of three intensive care units (ICUs), a prospective comparison of three pairs of intra-arterial and oscillometric BP readings was performed among patients with arrhythmia and an arterial line already present. After each inclusion in the arrhythmia group, one patient with regular rhythm was included as a control. International Organization for Standardization (ISO) standard validation required a mean bias 10 mm Hg) in our ICU population. The ability of oscillometry to detect hypotension (systolic BP 140 mm Hg) was good and similar during arrhythmia and regular rhythm (respective areas under the receiver operating characteristic curves ranging from 0.89 to 0.96, arrhythmia vs regular rhythm between-group comparisons all associated with P>0.3). Contrary to widespread belief, arrhythmia did not cause flawed automated brachial cuff measurements.Keywords
This publication has 30 references indexed in Scilit:
- Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure MonitoringHypertension, 2013
- Automated blood pressure measurement in atrial fibrillationJournal Of Hypertension, 2012
- Results of a survey of blood pressure monitoring by intensivists in critically ill patients: A preliminary studyCritical Care Medicine, 2010
- European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adultsBlood Pressure Monitoring, 2010
- Pression artérielle non invasive : principes et indications aux urgences et en réanimationRéanimation, 2009
- Atrial fibrillation—the growing epidemicHeart, 2007
- Measuring Level of Sedation in the Intensive Care UnitJAMA, 2000
- The Fast Flush Test Measures the Dynamic Response of the Entire Blood Pressure Monitoring SystemAnesthesiology, 1992
- Measuring blood pressure in the elderly: does atrial fibrillation increase observer variability?BMJ, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986