Extensibility of the Actin and Myosin Filaments in Various States of Skeletal Muscle as Studied by X-Ray Diffraction
Authors:
- 1 January 1998
- book chapter
- Published by Springer Nature
- Vol. 453, 309-317
Abstract
The effects of length changes applied to resting, contracting and rigor muscles on the reflection spacings of the X-ray diffraction patterns were summarized. The spacing changes of the actin- and myosin-based meridional reflections as a function of tension relative to an isometric tension of active muscle (P0) were linear and almost indentical in the active and rigor states, showing that the extension of both filaments is Hookenian and does not depend upon the states of muscle. In addition to their length changes caused by tension generation, there are small but significant length changes of both filaments due purely to activation of muscle. The actin and myosin filaments are elongated by ∼0.36% and ∼0.43%, respectively under the maximum active tension. The results indicate that a large part of the sarcomere compliance of an active muscle is caused by the extensibility of the myofilaments. Inspection of the behavior of the meridional and layer-line reflection spacings reveals that there is a close relationship between the extensibility and helical twisting of the actin filaments under active and passive forces. The extension caused by tension is associated with an unwinding of right-handed helices following the actin monomers in the filament. At the pointed end of the filament could rotate anticlockwise through one fifth the complete turn during contraction.Keywords
This publication has 15 references indexed in Scilit:
- Compliance of thin filaments in skinned fibers of rabbit skeletal muscleBiophysical Journal, 1995
- X-ray diffraction evidence for the extensibility of actin and myosin filaments during muscle contractionBiophysical Journal, 1994
- X-ray diffraction measurements of the extensibility of actin and myosin filaments in contracting muscleBiophysical Journal, 1994
- Actin compliance: are you pulling my chain?Biophysical Journal, 1994
- Right-handed rotation of an actin filament in an in vitro motile systemNature, 1993
- Imaging plate and its application to X-ray diffraction of muscleAdvances in Biophysics, 1991
- Design of small-angle X-ray diffractometer using synchrotron radiation at the photon factoryNuclear Instruments and Methods in Physics Research, 1983
- Symmetry and molecular arrangement in paracrystals of reconstituted muscle thin filamentsJournal of Molecular Biology, 1975
- X-ray evidence for conformational changes in the myosin filaments of vertebrate striated muscleJournal of Molecular Biology, 1975
- The low-angle X-ray diagram of vertebrate striated muscle and its behaviour during contraction and rigorJournal of Molecular Biology, 1967