Effects of air inlet or outlet position of a fan coil unit ventilation system on smoke movement and fire severity
Authors:
- 7 May 2020
- journal article
- research article
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 20 (2) , 103-117
Abstract
Air conditioning engineers design the inlet or outlet position of a fan coil unit (FCU) system according to thermal comfort and cost. However, the effect of the position on fire growth has not been considered. In this study, the effect of the relative inlet and outlet positions was investigated. Thirty cases were simulated using fire dynamics simulator (FDS). The simulation results revealed that the air inlet and outlet positions influence the smoke movement, doorway temperature and time to flashover. The air inlet is best installed near the door because the downward flowing cold air can cool the hot smoke exiting from the door. The air outlet positioned far from the doorway efficiently enables the smoky air to move outward, while it positioned near the doorway exhausts some fresh air. Furthermore, the air outlet position has a larger influence on flashover than the air inlet position. The air outlet immediately exhausts the smoke.Keywords
This publication has 24 references indexed in Scilit:
- The Theory of Thermal Comfort in Naturally Ventilated Indoor Environments - “The Pleasure Principle”International Journal of Ventilation, 2009
- Optimized design of floor-based air-conditioners for residential useBuilding and Environment, 2009
- Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatreEnergy and Buildings, 2008
- AN EXPERIMENTAL FIRE IN COMPARTMENT WITH DUAL VENT ON OPPOSITE WALLSCombustion Science and Technology, 2007
- Selective Quantification of Trace Palladium in Road Dusts and Roadside Soils by Displacement Solid-Phase Extraction Online Coupled with Electrothermal Atomic Absorption SpectrometryEnvironmental Science & Technology, 2004
- Experimental Study of Factors That Affect Thermal Comfort in an Upward-Displacement Air-Conditioned RoomHVAC&R Research, 2002
- Numerical studies of airflows induced by mechanical ventilation and air-conditioning (MVAC) systemsApplied Energy, 2001
- Performance criteria used in fire safety designAutomation in Construction, 1999
- Numerical studies on the indoor air flow in the occupied zone of ventilated and air-conditioned spaceBuilding and Environment, 1996
- Fire Induced Flow Field - Theory And ExperimentFire Safety Science, 1989