Sample Flow Rate Scan in Electrospray Ionization Mass Spectrometry Reveals Alterations in Protein Charge State Distribution
- 6 September 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 13042-13049
Abstract
Sample flow rate is one of the parameters that influence sensitivity of electrospray ionization (ESI) mass spectrometry. By varying sample flow rate, initial droplets of different size can be generated. Protein molecules in small droplets form gas-phase ions earlier than the ones in large droplets. Here, we have systematically studied the influence of sample flow rate on the ESI charge state distributions of model proteins. A dedicated programmable sample flow rate scanner was used to infuse protein samples at different flow rates into mass spectrometer. Synergistic influence of sample flow rate and various electrolytes (ammonium acetate, ammonium bicarbonate, ammonium formate, and piperidine) was studied. Significant alterations to the charge state distributions with increasing flow rate were observed. For example, in the presence of ammonium acetate, at low flow rates, lower charge states of proteins showed high intensities, while at high flow rates, ions related to higher charge states of proteins dominated the spectra. On the other hand, in the presence of piperidine, a significant reduction in the ion currents of all charge states was observed during the flow rate scan. Our observations suggest that at low flow rates the protein molecules follow charged residue model of ionization mechanism, and at high flow rates—due to structural changes in protein molecules in large ESI droplets—the charged residue and chain ejection models can possibly co-exist. We propose the use of sample flow rate scan as a way to reveal the influence of flow rate on charge state distribution of studied proteins.Keywords
Funding Information
- Ministry of Education
- National Tsing Hua University (109QI009E1)
- Ministry of Science and Technology, Taiwan (104-2628-M-007-006-MY4, 105-2113-M-009-018-MY3, 108-2113-M-007-017, 109-2634-F-007-023)
This publication has 74 references indexed in Scilit:
- Mass spectrometry methods for intrinsically disordered proteinsThe Analyst, 2013
- Electrothermal Supercharging of Proteins in Native Electrospray IonizationAnalytical Chemistry, 2012
- Electrospray Ionization Mass Spectrometry: A Technique to Access the Information beyond the Molecular Weight of the AnalyteInternational Journal of Analytical Chemistry, 2012
- Principles of Electrospray IonizationMolecular & Cellular Proteomics, 2011
- Negative Electrospray Droplet Exposure to Gaseous Bases for the Manipulation of Protein Charge State DistributionsAnalytical Chemistry, 2010
- Electrospray Droplet Exposure to Gaseous Acids for the Manipulation of Protein Charge State DistributionsAnalytical Chemistry, 2010
- New reagents for increasing ESI multiple charging of proteins and protein complexesJournal of the American Society for Mass Spectrometry, 2010
- Stepwise evolution of protein native structure with electrospray into the gas phase, 10 −12 to 10 2 sProceedings of the National Academy of Sciences of the United States of America, 2008
- Decharging of Globular Proteins and Protein Complexes in ElectrosprayChemistry – A European Journal, 2005
- Structure of ubiquitin refined at 1.8 Å resolutionJournal of Molecular Biology, 1987