Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter
- 27 January 2017
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (4) , N73-N89
Abstract
Most solid-state detectors, including 3D dosimeters, show lower signal in the Bragg peak than expected, a process termed quenching. The purpose of this study was to investigate how variation in chemical composition of a recently developed radiochromic, silicone-based 3D dosimeter influences the observed quenching in proton beams. The dependency of dose response on linear energy transfer, as calculated through Monte Carlo simulations of the dosimeter, was investigated in 60 MeV proton beams. We found that the amount of quenching varied with the chemical composition: peak-to-plateau ratios (1 cm into the plateau) ranged from 2.2 to 3.4, compared to 4.3 using an ionization chamber. The dose response, and thereby the quenching, was predominantly influenced by the curing agent concentration, which determined the dosimeter’s deformation properties. The dose response was found to be linear at all depths. All chemical compositions of the dosimeter showed dose-rate dependency; however this was not dependent on the linear energy transfer. Track-structure theory was used to explain the observed quenching effects. In conclusion, this study shows that the silicone-based dosimeter has potential for use in measuring 3D-dose-distributions from proton beams.Keywords
Funding Information
- Kræftens Bekæmpelse (R56-A2927-12-S2)
This publication has 25 references indexed in Scilit:
- FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation propertiesPhysics in Medicine & Biology, 2015
- Flexydos3D: A new deformable anthropomorphic 3D dosimeter readout with optical CT scanningJournal of Physics: Conference Series, 2015
- Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimetersPhysics in Medicine & Biology, 2015
- Integration and evaluation of automated Monte Carlo simulations in the clinical practice of scanned proton and carbon ion beam therapyPhysics in Medicine & Biology, 2014
- SHIELD-HIT12A - a Monte Carlo particle transport program for ion therapy researchJournal of Physics: Conference Series, 2014
- High resolution dosimetry in monoenergetic proton beam therapy on a normoxic polymer gel: the importance of high spatial resolution for reduced Bragg-Peak-quenchingJournal of Physics: Conference Series, 2013
- Water and tissue equivalence of a new PRESAGE® formulation for 3D proton beam dosimetry: A Monte Carlo studyMedical Physics, 2012
- Polymer gel dosimetryPhysics in Medicine & Biology, 2010
- Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiationRadiation Protection Dosimetry, 2006
- Ferrous sulphate gel dosimetry and MRI for proton beam dose measurementsPhysics in Medicine & Biology, 1999