Abstract
To evaluate the use, structural principles, operation, and acquired reproducibility of a respiratory monitoring device to be used for voluntary patient breath holding. Evaluation was performed of a respiratory monitoring device that enables determination of the respiratory level in a patient by measuring the movement of two contacts on the abdomen and chest wall. Neither metallic nor electronic materials are used in the mechanics for this device. The initial study group comprised 21 consecutive patients (15 men, six women; mean age, 75 years; range, 56-92 years) with lung or abdominal tumors who underwent examination with the device and computed tomography (CT) for three-dimensional reproducibility of lung base position during voluntary breath holding with or without use of the device. One patient with mild dementia was excluded; in most of the remaining 20 patients, high reproducibility of the breath-holding position was achieved in a short time with the device. In these 20 patients who were able to adapt to use of the device, three-dimensional mean maximum differences in lung base position during three random voluntary breath holds were 2.0 mm along the cranial-caudal axis, 1.5 mm along the anterior-posterior axis, and 1.2 mm along the right-left axis. The differences in all axes were significantly smaller with use of the respiratory monitoring device than without the device. The device demonstrates satisfactory reproducibility of voluntary patient breath holding easily and inexpensively and may offer a convenient device for easy use during irradiation with voluntary breath-holding conditions that require a small internal margin.Keywords
This publication has 15 references indexed in Scilit:
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- CT Fluoroscopy–guided Biopsy of the Lung or Upper Abdomen with a Breath-hold Monitoring and Feedback System: A Prospective Randomized Controlled Clinical TrialRadiology, 2005
- Four‐dimensional radiotherapy planning for DMLC‐based respiratory motion trackingMedical Physics, 2005
- Clinical outcomes of stereotactic radiotherapy for stage I non-small cell lung cancer using a novel irradiation technique: patient self-controlled breath-hold and beam switching using a combination of linear accelerator and CT scannerLung Cancer, 2004
- A feasibility study on the prediction of tumour location in the lung from skin motionBritish Journal of Radiology, 2004
- Validation of target volume and position in respiratory gated CT planning and treatmentMedical Physics, 2003
- CT evaluation of patient deep inspiration self‐breath‐holding: How precisely can patients reproduce the tumor position in the absence of respiratory monitoring devices?Medical Physics, 2003
- Quantifying the predictability of diaphragm motion during respiration with a noninvasive external markerMedical Physics, 2003
- Radiothérapie des cancers du poumon : le blocage en inspiration sous contrôle spirométriqueCancer/Radiothérapie, 2002
- Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT.Radiology, 1990