Radio Frequency Coils for Hyperpolarized 13C Magnetic Resonance Experiments with a 3T MR Clinical Scanner: Experience from a Cardiovascular Lab
Authors:
- Giulio GiovannettiGGGiulio Giovannetti
- Alessandra FloriAFAlessandra Flori
- Maria Filomena SantarelliMaria Filomena Santarelli
- Vincenzo PositanoVincenzo Positano
- Nicola MartiniNMNicola Martini
- Roberto FrancischelloRFRoberto Francischello
- Rolf F. SchulteRSRolf F. Schulte
- Jan Henrik Ardenkjaer-LarsenJan Henrik Ardenkjaer-Larsen
- Luca MenichettiLMLuca Menichetti
- Giovanni Donato AquaroGAGiovanni Donato Aquaro
- Andrea BarisonABAndrea Barison
- Francesca FrijiaFFFrancesca Frijia
Open Access
- 3 February 2021
- journal article
- review article
- Published by MDPI AG in Electronics
- Vol. 10 (4) , 366
Abstract
Hyperpolarized 13C magnetic resonance (MR) is a promising technique for the noninvasive assessment of the regional cardiac metabolism since it permits heart physiology studies in pig and mouse models. The main objective of the present study is to resume the work carried out at our electromagnetic laboratory in the field of radio frequency (RF) coil design, building, and testing. In this paper, first, we review the principles of RF coils, coil performance parameters, and estimation methods by using simulations, workbench, and MR imaging experiments. Then, we describe the simulation, design, and testing of different 13C coil configurations and acquisition settings for hyperpolarized studies on pig and mouse heart with a clinical 3T MRI scanner. The coil simulation is performed by developing a signal-to-noise ratio (SNR) model in terms of coil resistance, sample-induced resistance, and magnetic field pattern. Coil resistance was calculated from Ohm’s law and sample-induced resistances were estimated with a finite-difference time-domain (FDTD) algorithm. In contrast, the magnetic field per unit current was calculated by magnetostatic theory and a FDTD algorithm. The information could be of interest to graduate students and researchers working on the design and development of an MR coil to be used in 13C studies.Keywords
Funding Information
- Italian Ministry of Health and Tuscany Region (GR-2016-02361586)
This publication has 70 references indexed in Scilit:
- Multi-site benchmarking of clinical 13C RF coils at 3TJournal of Magnetic Resonance, 2020
- Metabolic and Molecular Imaging with Hyperpolarised TracersMolecular Imaging and Biology, 2018
- Magnetic resonance imaging with hyperpolarized agents: methods and applicationsPhysics in Medicine & Biology, 2017
- Technological Innovations in Magnetic Resonance for Early Detection of Cardiovascular DiseasesCurrent Pharmaceutical Design, 2015
- MRS: a noninvasive window into cardiac metabolismNMR in Biomedicine, 2015
- Models and Methods in Cardiac Imaging for Metabolism StudiesCurrent Pharmaceutical Design, 2014
- Dynamic nuclear polarization polarizer for sterile use intentNMR in Biomedicine, 2011
- Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMRProceedings of the National Academy of Sciences of the United States of America, 2003
- 13C NMR of Intermediary Metabolism: Implications for Systemic PhysiologyAnnual Review of Physiology, 2001
- NMR probeheads forin vivo applicationsConcepts in Magnetic Resonance, 2000