Hydrogen Induced Cracking Failure of ASTM a 516 Grade 70 Steel in near Neutral to High pH Solution
Authors:
- 16 March 2003
- conference paper
- Published by Association for Materials Protection and Performance (AMPP)
- p. 1-12
Abstract
The hydrogen uptake behavior of ASTM A 516 grade 70/grade 60 (UNS K02700 I UNS K02100) steels was studied in near neutral and high pH solutions representing aqueous alkanolamine/sulfolane* solutions used in gas sweetening operations (removal of hydrogen sulfide and carbon dioxide). Since known test techniques for hydrogen charging activities did not reveal sufficient sensitivity for hydrogen uptake a unique modification of fracture mechanics J-integral testing methodology was employed. The tests were complemented with slow-strain-rate-testing. In contact with high pH solutions the steels investigated showed only minor hydrogen uptake without a high potential for hydrogen induced cracking (HIC) formation. However, when in contact to lower pH solutions (pH below 7.1) hydrogen uptake was significant and HIC can develop at non-metallic inclusions. It was also concluded, typical service conditions for aqueous alkanolamine/sulfolane solutions do not impose a severe risk for HIC. Modern HIC resistant steels tend to degrade by HIC at a much lower pH than considered in this study for aqueous alkanolamine/sulfolane solutions.Keywords
This publication has 3 references indexed in Scilit:
- Equilibrium solubility of H2S and CO2 and their mixtures in a mixed solventThe Canadian Journal of Chemical Engineering, 1991
- Hydrogen Effect on Remaining Life of Hydroprocessing ReactorsCorrosion, 1988
- Solubility of hydrogen sulfide and carbon dioxide in aqueous methyldiethanolamine solutionsIndustrial & Engineering Chemistry Process Design and Development, 1982