Abstract
Measurement of the stress and strain applied to implants and bone tissue in the human body are important for fracture prediction and evaluations of implant adaptation. The strain of titanium (Ti) materials can be measuring by X-ray diffraction techniques. This study applied X-ray diffraction to the skin tissue-covered Ti. Characteristic X-rays of were used and the X-rays diffracted from the Ti were detected through the covering skin tissue. The X-ray absorption by skin tissue is large under the diffracted X-rays detected in low angles because the length of penetration depends on the angle of inclination, equal to the Bragg angle. The effects of skin tissue to detect the diffracted X-rays were investigated in the experiments. And the strain measurements were conducted under bending loads applied to the Ti specimen. The effect of skin tissue was absorption of X-rays as well as the X-rays scattered from the physiological saline contained in the tissue. The X-rays scattered by the physiological saline creates a specific background pattern near the peaks from the (002) and (011) lattice planes of Ti in the X-ray diffraction profile. Diffracted X-rays from the Ti were detected after being transmitted through 1 mm thick skin tissue by . Individual peaks such as (010), (002), (011), and (110) were clearly established by using a parallel beam arrangement. The strains of (110) lattice planes were measured with or without the tissue cover were very similar. The strain of the (110) lattice planes of Ti could be measured by when the Ti specimen was located under the skin tissue.
Keywords
This publication has 16 references indexed in Scilit:
- Ti based biomaterials, the ultimate choice for orthopaedic implants – A reviewProgress in Materials Science, 2009
- Understanding site-specific residual strain and architecture in bovine cortical boneJournal of Biomechanics, 2008
- Estimating nanoscale deformation in bone by X-ray diffraction imaging methodJournal of Biomechanics, 2008
- Micromechanical response of mineral and collagen phases in boneJournal of Structural Biology, 2007
- Relationship between bone tissue strain and lattice strain of HAp crystals in bovine cortical bone under tensile loadingJournal of Biomechanics, 2007
- Cooperative deformation of mineral and collagen in bone at the nanoscaleProceedings of the National Academy of Sciences, 2006
- Strain measurements in bovine cortical bone using X-ray imaging plate systemJournal of Biomechanics, 2006
- Internal strains and stresses measured in cortical bone via high-energy X-ray diffractionJournal of Structural Biology, 2005
- Polychromatic X-ray Measurements of Anisotropic Residual Stress in Bovine Femoral Bone.JSME International Journal Series C, 2000
- Water content in type I collagen tissues calculated from the generalized packing modelInternational Journal of Biological Macromolecules, 1986