Developments in microfabrication of mineral samples for simultaneous EBSD–EDS analysis utilizing an FIB–SEM instrument: study on an S–type cosmic spherule from Antarctica
Open Access
- 1 January 2020
- journal article
- research article
- Published by Japan Association of Mineralogical Sciences in Journal of Mineralogical and Petrological Sciences
- Vol. 115 (5) , 407-415
Abstract
A focused ion beam (FIB) scanning electron microscope (SEM) equipped with a low–energy Ar–ion gun, an electron back–scattered diffraction (EBSD) detector, and an energy dispersive spectrometer (EDS) was newly developed for microfabrication, followed by submicroscopic chemical and crystallographic analyses in an identical sample chamber. The surface condition of mineral samples requires extreme care during FIB milling process, especially for EBSD measurement, as the EBSD pattern is greatly affected by a damaged amorphous surface caused by a high–energy Ga–ion beam (30 keV), even when this damaged layer is only tens of nanometers in thickness. Low–energy broad Ar–ion beam milling (1 keV) overcomes this problem and allows us to obtain sharp EBSD patterns. We applied the microfabrication–analysis protocol to a cosmic spherule. Comprehensive mineralogical datasets from SEM images, X–ray elemental maps, and EBSD patterns were successfully obtained from a minute mineral sample, where conventional cutting and polishing processes are not possible.Keywords
This publication has 20 references indexed in Scilit:
- Electron backscatter diffraction (EBSD) analyses of phyllosilicates in petrographic thin sectionsAmerican Mineralogist: Journal of Earth and Planetary Materials, 2012
- In-situ Low Energy Argon Ion Milling of Nanoelectronic Structures Using a Triple Beam SystemMicroscopy and Microanalysis, 2009
- Focused Ion Beam (FIB) combined with SEM and TEM: Advanced analytical tools for studies of chemical composition, microstructure and crystal structure in geomaterials on a nanometre scaleChemical Geology, 2009
- The classification of micrometeoritesMeteoritics & Planetary Science, 2008
- Improved EBSD Sample Preparation Via Low Energy Ga+ FIB Ion MillingMicroscopy and Microanalysis, 2007
- Comet 81P/Wild 2 Under a MicroscopeScience, 2006
- 2 keV Ga+ FIB Milling for Reducing Amorphous Damage in SiliconMicroscopy and Microanalysis, 2005
- Combining Ar ion milling with FIB lift‐out techniques to prepare high quality site‐specific TEM samplesJournal of Microscopy, 2004
- Extraterrestrial water in micrometeorites and cosmic spherules from Antarctica: An ion microprobe studyMeteoritics & Planetary Science, 1999
- Use of the Hough transformation to detect lines and curves in picturesCommunications of the ACM, 1972