Development and evaluation of a multiplex droplet digital polymerase chain reaction method for simultaneous detection of five biothreat pathogens
Open Access
- 28 July 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 13, 970973
Abstract
Biothreat agents pose a huge threat to human and public health, necessitating the development of rapid and highly sensitive detection approaches. This study establishes a multiplex droplet digital polymerase chain reaction (ddPCR) method for simultaneously detecting five high-risk bacterial biothreats: Yersinia pestis, Bacillus anthracis, Brucella spp., Burkholderia pseudomallei, and Francisella tularensis. Unlike conventional multiplex real-time PCR (qPCR) methods, the multiplex ddPCR assay was developed using two types of probe fluorophores, allowing the assay to perform with a common two-color ddPCR system. After optimization, the assay performance was evaluated, showing a lower limit of detection (LOD) (0.1–1.0 pg/μL) and good selectivity for the five bacteria targets. The multiplex assay’s ability to simultaneously detect two or more kinds of targets in a sample was also demonstrated. The assay showed strong sample tolerance when testing simulated soil samples; the LOD for bacteria in soil was 2 × 102–2 × 103 colony-forming unit (CFU)/100 mg soil (around 5–50 CFU/reaction), which was 10-fold lower than that of the single-target qPCR method. When testing simulated soil samples at bacterial concentrations of 2 × 103–2 × 104 CFU/100 mg soil, the assay presented a higher sensitivity (100%, 35/35) than that of the qPCR method (65.71%, 23/35) and a good specificity (100%, 15/15). These results suggest that the developed 5-plex ddPCR method is more sensitive than conventional qPCR methods and is potentially suitable for rapidly detecting or screening the five selected bacterial biothreats in suspicious samples.Keywords
This publication has 31 references indexed in Scilit:
- Absolute quantification by droplet digital PCR versus analog real-time PCRNature Methods, 2013
- Estimated copy number of Bacillus anthracis plasmids pXO1 and pXO2 using digital PCRJournal of Microbiological Methods, 2013
- Evaluation of the FilmArray ® system for detection of Bacillus anthracis, Francisella tularensis and Yersinia pestisJournal of Applied Microbiology, 2013
- Evaluation of two multiplex real-time PCR screening capabilities for the detection of Bacillus anthracis, Francisella tularensis and Yersinia pestis in blood samples generated from murine infection modelsJournal of Medical Microbiology, 2012
- The Potential of TaqMan Array Cards for Detection of Multiple Biological Agents by Real-Time PCRPLOS ONE, 2012
- CLSI EP17-A protocol: A useful tool for better understanding the low end performance of total prostate-specific antigen assaysClinica Chimica Acta, 2011
- Ambient Stable Quantitative PCR Reagents for the Detection of Yersinia pestisPLOS Neglected Tropical Diseases, 2010
- Molecular Evolutionary Consequences of Niche Restriction in Francisella tularensis, a Facultative Intracellular PathogenPLOS Pathogens, 2009
- Effects of Long-Term Storage on Plasmid Stability in Bacillus anthracisApplied and Environmental Microbiology, 2005
- Development of a Multitarget Real-Time TaqMan PCR Assay for Enhanced Detection of Francisella tularensis in Complex SpecimensJournal of Clinical Microbiology, 2003