Flux signature analysis: An alternative method for the fault diagnosis of induction machines

Authors:

Abstract
Intensive research efforts have been focused on the signature analysis (SA) to detect electrical and mechanical faults of induction machines. Different signals can be used: voltage, current, flux and power. In the case of current signals (CSA), the interpretation of one-phase current spectrum or the three-phase current space vector spectrum provides direct information on the presence of abnormal conditions. With proper operative condition, a similar interpretation can be obtained by using flux sensor (FSA). In this paper, it is proved that a simple external leakage flux sensor is more efficient than the classical motor current signature analysis (MCSA) to detect both stator and rotor faults in induction machines.