Abstract
Intensive research efforts have been focused on the signature analysis (SA) to detect electrical and mechanical faults of induction machines. Different signals can be used: voltage, current, flux and power. In the case of current signals (CSA), the interpretation of one-phase current spectrum or the three-phase current space vector spectrum provides direct information on the presence of abnormal conditions. With proper operative condition, a similar interpretation can be obtained by using flux sensor (FSA). In this paper, it is proved that a simple external leakage flux sensor is more efficient than the classical motor current signature analysis (MCSA) to detect both stator and rotor faults in induction machines.Keywords
This publication has 9 references indexed in Scilit:
- Condition monitoring of wind generators2004
- A general purpose software for signal processing oriented to the diagnosis of electrical machines2004
- Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults2003
- A general purpose software for distance monitoring and diagnosis of electrical machines2003
- A frequency-domain detection of stator winding faults in induction machines using an external flux sensorIEEE Transactions on Industry Applications, 2003
- Fault diagnosis in induction motors using radial magnetic field measurement with an antennaMeasurement Science and Technology, 2003
- Quantitative evaluation of induction motor broken bars by means of electrical signature analysisIEEE Transactions on Industry Applications, 2001
- Closed-loop control impact on the diagnosis of induction motors faultsIEEE Transactions on Industry Applications, 2000
- Methods of Motor Current Signature AnalysisElectric Machines & Power Systems, 1992