Abstract
A study has been made of the effect of quenching rate on the structure and intergranular corrosion susceptibility of 2024 aluminum alloy. Polarization and potential data were obtained separately on the three (simulated) phases of the alloy: (1) solid solution of aluminum-4 percent copper-1.5 percent magnesium; (2) the depleted zone, represented by high purity aluminum; (3) the precipitate CuAl2. Specimens of 2024 alloy which were not susceptible and highly susceptible, respectively, to intergranular corrosion were also tested. Curves were plotted of cooling rate vs corrosion potential of the 2024 alloy specimens. Potential-time curves of the various phases in the alloy were also drawn. It was shown that as quenching rate decreases, intergranular corrosion susceptibility increases. This was the initial attempt to determine the electrochemical relationships between the phases in 2024 aluminum alloy with varying degrees of susceptibility to intergranular corrosion.

This publication has 1 reference indexed in Scilit: