Design and test results of a front-end ASIC for radiation detectors
Authors:
- 1 October 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1717-1720
Abstract
A front-end ASIC for semiconductor radiation detectors is presented. It is composed of a Charge Sensitive Amplifier (CSA), a pulse shaper, and a Peak Detect and Hold (PDH) circuit. Poly-resistor is used as source degeneration component to reduce the noise of current source in the CSA. The ASIC has been designed in a 0.5 ¿m CMOS DPTM technology and tested with Verigy 93000. The gain (PDH excluded) is 78.5 mV/fC and the Equivalent Noise Charge (ENC) with detector disconnected is 800-900 e. The power dissipation without the output buffer is about 2.6 mW.Keywords