Naphthoquinone glycosides for bioelectroanalytical enumeration of the faecal indicator Escherichia coli
Open Access
- 1 July 2016
- journal article
- research article
- Published by Wiley in Microbial Biotechnology
- Vol. 9 (6) , 746-757
Abstract
Summary: Microbial water quality monitoring for the presence of faecal indicator bacteria ( FIB ) is a mandatory activity in many countries and is key in public health protection. Despite technological advances and a need for methodological improvements, chromogenic and fluorogenic enzymatic techniques remain the mainstays of water quality monitoring for both public health agencies and regulated utilities. We demonstrated that bioelectroanalytical approaches to FIB enumeration are possible and can be achieved using commercially available enzyme‐specific resorufin glycosides, although these are expensive, not widely available or designed for purpose. Following this, we designed two naphthoquinone glycosides which performed better, achieving Escherichia coli detection in the range 5.0 × 10 2 to 5.0 × 10 5 CFU ml −1 22–54% quicker than commercially available resorufin glycosides. The molecular design of the naphthoquinone glycosides requires fewer synthetic steps allowing them to be produced for as little as US $50 per kg. Tests with environmental samples demonstrated the low tendency for abiotic interference and that, despite specificity being maintained between β‐glucuronidase and β‐galactosidase, accurate enumeration of E. coli in environmental samples necessitates development of a selective medium. In comparison to a commercially available detection method, which has U.S. Environmental Protection Agency ( EPA ) approval, our approach performed better at high organism concentrations, detecting 500 organisms in 9 h compared with 13.5 h for the commercial method. Bioelectroanalytical detection is comparable to current approved methods and with further development could result in improved detection times. A recent trend for low‐cost open‐source hardware means that automated, potentiostatically controlled E. coli detection systems could be constructed for less than US $100 per channel.Keywords
Funding Information
- National Research Foundation
- Ministry of Education
- Nanyang Technological University
- National University of Singapore
This publication has 55 references indexed in Scilit:
- Performance Characteristics of qPCR Assays Targeting Human- and Ruminant-AssociatedBacteroidetesfor Microbial Source Tracking across Sixteen Countries on Six ContinentsEnvironmental Science & Technology, 2013
- Improving charge collection in Escherichia coli–carbon electrode devices with conjugated oligoelectrolytesPhysical Chemistry Chemical Physics, 2013
- Autonomous, Wireless In-Situ Sensor (AWISS) for Rapid Warning of Escherichia coli Outbreaks in Recreational and Source WatersEnvironmental Engineering Science, 2011
- CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational ApplicationsPLOS ONE, 2011
- Water Microbiology. Bacterial Pathogens and WaterInternational Journal of Environmental Research and Public Health, 2010
- A Critical Examination of Escherichia coli Esterase ActivityJournal of Biological Chemistry, 2009
- Novel indirect enzyme-linked immunosorbent assay (ELISA) method to detect Total E. coli in water environmentAnalytica Chimica Acta, 2007
- Pathogen detection: A perspective of traditional methods and biosensorsBiosensors and Bioelectronics, 2007
- Microbial contamination of drinking water and disease outcomes in developing regionsToxicology, 2004
- Rapid detection of Escherichia coli in water by a culture-based amperometric methodAnalytica Chimica Acta, 2001