MRI gradient waveform design by numerical optimization
Authors:
- 1 April 1993
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 29 (4) , 498-504
Abstract
This manuscript describes a method of gradient waveform design by nonlinear constrained optimization. Methods of formulation and solution of the waveform optimization problem are briefly described for minimization of root mean squared current and minimization of waveform moments. Waveforms generated using these objectives are presented and compared with those obtained with other objectives. The method uses waveforms which are defined as a set of discrete amplitudes in order to remove artificial constraints on waveform shape imposed by “multilobe” designs. These point-to-point amplitudes are the parameters determined in the optimization procedure which includes knowledge of the specific imaging conditions and the specific gradient hardware system. Some beneficial results of this design approach are: a) physically realizable waveforms which optimally achieve specific imaging and motion artifact reduction goals, b) waveforms which are guaranteed to be optimal with respect to one of several possible objective, c) less reliance on the experience of the designer, and d) a potential reduction in waveform design time.Keywords
This publication has 18 references indexed in Scilit:
- Significance of the point of expansion in interpretation of gradient moments and motion sensitivityJournal of Magnetic Resonance Imaging, 1991
- A progressive gradient moment nulling design techniqueMagnetic Resonance in Medicine, 1991
- Interactive design of motion‐compensated gradient waveforms with a personal computer spreadsheet programJournal of Magnetic Resonance Imaging, 1991
- Gradient moment nulling through the N11th moment. Application of binomial expansion coefficients to gradient amplitudesJournal of Magnetic Resonance (1969), 1988
- MR Angiography with Gradient Motion RefocusingJournal of Computer Assisted Tomography, 1988
- Improving MR image quality in the presence of motion by using rephasing gradientsAmerican Journal of Roentgenology, 1987
- Motion Artifact Suppression Technique (MAST) for MR ImagingJournal of Computer Assisted Tomography, 1987
- Spatial or flow velocity phase encoding gradients in NMR imagingMagnetic Resonance Imaging, 1984
- Direct Cardiac NMR Imaging of Heart Wall and Blood Flow VelocityJournal of Computer Assisted Tomography, 1984
- The generalized simplex method for minimizing a linear form under linear inequality restraintsPacific Journal of Mathematics, 1955