Measurement of entrained air-void parameters in Portland cement concrete using micro X-ray computed tomography
Authors:
- 17 April 2016
- journal article
- research article
- Published by Taylor & Francis in International Journal of Pavement Engineering
- Vol. 19 (2) , 109-121
Abstract
The entrained air-void system in concrete is closely related to freeze-thaw durability in concrete pavements or other structures. For either research or forensic purposes, reliable and economical methods for the quantification of entrained air are desirable. This study explores the potential of using micro X-ray computed tomography (μCT) to measure entrained air-void parameters in concrete. A series of small cores (6 mm dia.) were retrieved from larger (100-mm-dia.) cores from two different concrete pavements, representing both adequate and marginal air contents, and scanned at a resolution of 7.5 μm/pixel. A systematic procedure based on image processing is proposed to address practical difficulties such as void/solid thresholding, air-type discernment (entrained air-voids vs. voids in aggregate) and the separation of bubbles within close proximity to each other (e.g. clustered air-voids). Air content and specific surface were measured directly from the three-dimensional (3D) reconstructed X-ray images, while values for paste content were derived from manual point counts performed on two-dimensional (2D) slices obtained from the 3D images. The derived values for air content, specific surface and paste content were used to calculate Powers’ spacing factor. To assess the issue of local fluctuations of material constituents and the limited dimensions of the small cores, uncertainty associated with the sample volume of concrete under measurement was also estimated. Based on the results in this study with regard to the work involved in sample preparation, data analysis and uncertainty bounds, μCT has been found to be a viable option for measurement of spacing factor and specific surface, but due to limitations imposed by the dimensions of the sample size (6-mm-dia. cores), the method is not appropriate for bulk air content determination.Keywords
This publication has 32 references indexed in Scilit:
- X-Ray Microtomography of Mortars Exposed to Freezing-Thawing ActionJournal of Advanced Concrete Technology, 2010
- Characterizing the 3D Pore Structure of Hardened Cement Paste with Synchrotron MicrotomographyJournal of Advanced Concrete Technology, 2008
- 3D experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (μCT)Cement and Concrete Research, 2007
- Development of Precision Statement for Determining Air Void Characteristics of Fresh Concrete with Use of Air Void AnalyzerTransportation Research Record: Journal of the Transportation Research Board, 2007
- X-ray microtomographic studies of pore structure and permeability in Portland cement concreteMaterials and Structures, 2006
- Sulfate attack monitored by microCT and EDXRD: Influence of cement type, water-to-cement ratio, and aggregateCement and Concrete Research, 2006
- Pore structure of cement/pozzolan composites by X-ray microtomographyCement and Concrete Research, 2005
- Active contours without edgesIEEE Transactions on Image Processing, 2001
- Precision of the air void characteristics measurement by ASTM C 457: results of an interlaboratory test programCanadian Journal of Civil Engineering, 1996
- Phase Transitions of Adsorbates: IV, Mechanism of Frost Action in Hardened Cement Paste*Journal of the American Ceramic Society, 1972