Technical Aspects of High-Resolution Color-Coded Duplex Sonography for the Design of Perforator Flaps
Authors:
- 17 January 2022
- journal article
- research article
- Published by Georg Thieme Verlag KG in Journal of Reconstructive Microsurgery
- Vol. 38 (03) , 181-192
Abstract
Background Technical aspects are of utmost significance for an efficient execution in designing perforator flaps with high-resolution color-coded Duplex sonography (CCDS). The following study evaluates decisive factors for a successful microvessel examination conducted by the microsurgeon. Methods Technical knowledge presented in this study was based on a series of more than 200 perforator flaps planned with CCDS. Flap reconstructions were performed at the University Hospital Regensburg, Germany, from July 2013 to January 2021. Standard high-resolution ultrasound (US) devices with linear multifrequency transducers of 4 to 18 MHz were used. Modes and device settings were evaluated regarding applicability by microsurgeons. Key steps for safe perforator identification and further optional steps for additional assessment should be discriminated. Results Different US modes including brightness mode (B-mode), color flow (CF), power Doppler (PD), pulse wave (PW), and blood flow (B-Flow) were used. Transducers from 15 MHz and up were favorable to detect microvessels. Knobology of a standard US device regarding buttons, switches, and specific onscreen options with relevance for perforator mapping was subcategorized in four different groups. For qualitative and quantitative evaluation of microvessels, different US modes were tested with respect to their usefulness.Vital elements of the CCDS exam are disaggregated into three key steps for safe perforator identification and three optional steps for further perforator characterization. A standardized protocol for the CCDS exams was applied. Downregulation of pulse-repetition frequency/scale to adapt device sensitivity to slow-flow velocities represented the most important criterion to visualize microvessels.Qualitative microvessel evaluation was performed in B-mode, CCDS, PD mode, and B-Flow mode. Quantitative assessment was executed using PW-mode and CCDS measuring the microvessels' diameter (mm) and flow characteristics. Quantitative information may be obtained using PW-mode and the distance-measuring tool in CF-mode. Conclusion Technical aspects with respect to proper device trimming and application decisively impact CCDS-guided perforator vessel identification and evaluation.Keywords
This publication has 32 references indexed in Scilit:
- Contrast‐enhanced ultrasound in the preoperative, intraoperative and postoperative assessment of liver lesionsHepatology Research, 2013
- Noninvasive Vascular Appropriateness Criteria—Review and Comments on the American College of Cardiology (ACC) GuidelinesJournal of the American Society of Echocardiography, 2013
- Diagnostic Efficacy of Color Doppler Ultrasonography in Preoperative Assessment of Anterolateral Thigh Flap Cutaneous PerforatorsPlastic and Reconstructive Surgery, 2013
- Non-invasive vascular imaging in perforator flap surgeryActa Radiologica, 2013
- Contrast-Enhanced Ultrasound Combined with Three-Dimensional Reconstruction in Preoperative Perforator Flap PlanningPlastic and Reconstructive Surgery, 2013
- Diagnostic Efficacy of Preoperative 64-Section Multidetector Computed Tomographic Angiography in Identifying the Cutaneous Perforators in the Anterolateral Thigh FlapPlastic and Reconstructive Surgery, 2012
- Preoperative Imaging for Perforator Flaps in Reconstructive SurgeryAnnals of Plastic Surgery, 2012
- Evaluation of Diagnostic Accuracy Using Preoperative Handheld Doppler in Identifying the Cutaneous Perforators in the Anterolateral Thigh FlapPlastic and Reconstructive Surgery, 2012
- Different Types of Suprafascial Courses in Thoracodorsal Artery Skin PerforatorsPlastic and Reconstructive Surgery, 2008
- Color-Flow Duplex Scanning in the Preoperative Assessment of TRAM Flap PerforatorsPlastic and Reconstructive Surgery, 1994