Abstract
Background  The chin‐down posture is generally recommended in patients with neurogenic dysphagia to prevent tracheal aspiration; however, its effectiveness has not been demonstrated.Aim  To videofluoroscopically (VDF) assess the effectiveness of chin‐down posture to prevent aspiration in patients with neurogenic dysphagia secondary to acquired brain injury.Methods  Randomized, alternating, cross‐over study (with and without the chin‐down posture) in 47 patients with a VDF diagnosis of aspiration [31 stroke, 16 traumatic brain injury (TBI)] and 25 controls without aspiration (14 stroke, 11 TBI).Key Results  During the chin‐down posture, 55% of patients avoided aspiration (40% preswallow aspiration and 60% aspiration during swallow). The percentage was similar in both etiologies (58% stroke and 50% TBI). Fifty‐one percent of patients had silent aspiration; of these, 48% persisted with aspiration while in the chin‐down posture. A statistically significant relationship was found between the existence of pharyngeal residue, cricopharyngeal dysfunction, pharyngeal delay time and bolus volume with the persistence of aspiration. The chin‐down posture did not change swallow biomechanics in patients without aspiration.Conclusions & Inferences  Only half the patients with acquired brain injury avoided aspiration during cervical flexion; 48% of silent aspirators continued to aspire during the maneuver. Several videofluoroscopic parameters were related to inefficiency of the maneuver. Therefore, the indication for chin‐down posture should be evaluated by videofluoroscopic examination.

This publication has 16 references indexed in Scilit: