Neutron irradiation test of depleted CMOS pixel detector prototypes
Authors:
Preprint
Abstract
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation. The test structures were produced for investigation of CMOS technology in tracking detectors for experiments at HL-LHC upgrade. Measurements were made with passive detector structures in which current pulses induced on charge collecting electrodes could be directly observed. Thickness of depleted layer was estimated and studied as function of neutron irradiation fluence. An increase of depletion thickness was observed after first two irradiation steps to 1$\cdot$10$^{13}$ n/cm$^{2}$ and 5$\cdot$10$^{13}$ n/cm$^{2}$ and attributed to initial acceptor removal. At higher fluences the depletion thickness at given voltage decreases with increasing fluence because of radiation induced defects contributing to the effective space charge concentration. The behaviour is consistent with that of high resistivity silicon used for standard particle detectors. The measured thickness of the depleted layer after irradiation with 1$\cdot$10$^{15}$ n/cm$^{2}$ is more than 50 $\mu$m at 100 V bias. This is sufficient to guarantee satisfactory signal/noise performance on outer layers of pixel trackers in HL-LHC experiments.Keywords
All Related Versions
- Version 1, 2017-01-18, ArXiv
- Published version: Journal of Instrumentation, 12 (2), P02021.
This publication has 21 references indexed in Scilit:
- Investigation of HV/HR-CMOS technology for the ATLAS Phase-II Strip Tracker UpgradeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- CMOS pixel sensors on high resistive substrate for high-rate, high-radiation environmentsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- A Monolithic Active Pixel Sensor for ionizing radiation using a 180nm HV-SOI processNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- DMAPS: a fully depleted monolithic active pixel sensor—analog performance characterizationJournal of Instrumentation, 2015
- Computational analysis of irradiation facilities at the JSI TRIGA reactorApplied Radiation and Isotopes, 2012
- Radiation damage in p-type silicon irradiated with neutrons and protonsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- CMS barrel pixel detector overviewNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- A monolithic active pixel sensor for charged particle tracking and imaging using standard VLSI CMOS technologyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Investigations of donor and acceptor removal and long term annealing in silicon with different boron/phosphorus ratiosNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Experimental confirmation of a new semiconductor detector principleNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990