BACKGROUND AND PURPOSE: Intraprocedural aneurysmal rupture is a feared complication of coil embolization of intracranial aneurysms and is associated with high rates of morbidity and mortality. We report the incidence, endovascular management, and clinical outcome of patients with IAR, with emphasis on the role of the balloon-assisted technique. MATERIALS AND METHODS: We conducted a retrospective analysis of all intracranial aneurysms treated by coil embolization between September 2001 and June 2011. All patients with IAR were studied. Comparison of immediate clinical outcomes was performed by using univariate analysis (Fisher exact test). RESULTS: Of 652 intracranial aneurysms treated with coil embolization, an IAR occurred in 22 (3.4%). Rupture occurred during placement of coils in 18 cases, microcatheters in 2 cases, and a guidewire in 1 case, and during induction of anesthesia in 1 case. Before treatment, 15 of 22 (68%) patients were in good clinical condition (WFNS grade I). There were fewer patients with worsening of the WFNS grade following an IAR when the balloon-assisted technique was used (7.7%) compared with when it was not (55.5%) (P = .023). Death occurred in 2 (9.1%) patients. CONCLUSIONS: IAR is a potentially serious complication of coil embolization. If IAR occurs, balloon-assistance is helpful in obtaining rapid hemostasis resulting in better short-term outcomes.Keywords
This publication has 26 references indexed in Scilit:
- Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experienceJournal of Neurosurgery, 2003
- Endovascular Treatment of Intracranial Aneurysms With Guglielmi Detachable CoilsStroke, 2002
- Outcomes after Aneurysm Rupture during Endovascular Coil EmbolizationNeurosurgery, 2001
- Rupture of Intracranial Aneurysms during Endovascular Coiling: Management and OutcomesNeurosurgery, 2001
- Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: incidence, outcome, and risk factorsJournal of Neurosurgery, 2001
- Ruptured Intracranial Aneurysms: Acute Endovascular Treatment with Electrolytically Detachable Coils—A Prospective Randomized StudyRadiology, 1999
- Selection of Cerebral Aneurysms for Treatment Using Guglielmi Detachable Coils: The Preliminary University of Illinois at Chicago ExperienceNeurosurgery, 1998
- Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coilsJournal of Neurosurgery, 1998
- Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment.Radiology, 1998
- Embolisation of recently ruptured intracranial aneurysms.Journal of Neurology, Neurosurgery & Psychiatry, 1995