Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimer
Authors:
- Bettina Kemkes-MatthesBKBettina Kemkes-Matthes
- Ronald FischerRFRonald Fischer
- Dirk PeetzDPDirk Peetz
- 1 April 2011
- journal article
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 22 (3) , 215-220
Abstract
This study evaluates the effect of whole blood storage on common coagulation parameters in order to confirm or revise acceptable storage limits as defined by current guidelines and diverse study reports. Aliquots were taken from the citrated whole blood of inpatients and outpatients (n = 147) within 4 h after blood withdrawal and after extended storage of whole blood for 8 and 24 h at ambient temperature. Aliquots were centrifuged and analyzed for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (Fbg), antithrombin (AT), thrombin time (TT) and D-dimer. For each parameter, samples from 33-56 patients were investigated covering a wide range of normal and pathological values. Samples from patients receiving heparin were excluded from analyses of APTT and TT. All assays were performed using reagents and an analyzer from Siemens Healthcare Diagnostics Products GmbH. The mean percentage change after 8 and 24-h storage was below 10% for all parameters. Considering the changes in individual samples, all parameters can be reliably tested after 8-h storage, since less than 15% of the samples demonstrated individual changes of above 10%. The acceptable storage time can be extended to 24 h for PT, TT and D-dimer. Clinically relevant changes were detected after 24-h storage for APTT: 41% of the investigated samples demonstrated changes of above 10%. After 24-h storage, changes for Fbg and AT values were more than 15% in five out of 49 and in three out of 45 samples, respectively. This sporadic increase of values is clinically acceptable except for borderline samples.Keywords
This publication has 10 references indexed in Scilit:
- Influence of temperature and time before centrifugation of specimens for routine coagulation testingInternational Journal of Laboratory Hematology, 2009
- A multicenter evaluation of a new quantitative highly sensitive D-dimer assay for exclusion of venous thromboembolismThrombosis and Haemostasis, 2008
- Stability of coagulation assays performed in plasma from citrated whole blood transported at ambient temperatureThrombosis and Haemostasis, 2008
- Preanalytical variables in coagulation testingBlood Coagulation & Fibrinolysis, 2007
- Quality and reliability of routine coagulation testing: can we trust that sample?Blood Coagulation & Fibrinolysis, 2006
- Cold storage of citrated whole blood induces drastic time-dependent losses in factor VIII and von Willebrand factor: potential for misdiagnosis of haemophilia and von Willebrand diseaseBlood Coagulation & Fibrinolysis, 2006
- Preanalytical Variables and Off-Site Blood Collection: Influences on the Results of the Prothrombin Time/International Normalized Ratio Test and Implications for Monitoring of Oral Anticoagulant TherapyClinical Chemistry, 2005
- Agreement of D-dimer Results Measured by a Rapid ELISA (VIDAS) before and after Storage during 24 h or Transportation of the Original Whole Blood SamplesThrombosis and Haemostasis, 2000
- The effect of time and temperature variables on routine coagulation testsBlood Coagulation & Fibrinolysis, 1998
- The determination of INR in stored whole blood.Journal of Clinical Pathology, 1998