Numerical Simulation of the Effect of Electrical Stimulation on Disuse After Hip Replacement
Open Access
- 14 February 2025
- journal article
- research article
- Published by MDPI AG in Biomedicines
- Vol. 13 (2) , 471
Abstract
Background: Total hip replacement replaces the femoral head, which cannot heal, with an artificial femoral shaft to ensure the patient’s normal life. However, due to the stress-masking effect of the proximal femur loaded with the artificial femur stem, the implant bears a large part of the load, resulting in insufficient stress stimulation of the proximal femur and bone waste remodeling. In turn, it is easy to lose bone, resulting in loosening. As a new treatment method, electrical stimulation has been widely used for bone loss, nonunion, and other diseases, and it has achieved good therapeutic effects. Methods: Therefore, in this work, electrical stimulation was introduced for postoperative density assessment, and a new disuse remodeling model was established to simulate density loss after remodeling and the resistance effect of electrical stimulation. The effects of various parameters on density loss in the model are discussed. Results: The simulation results revealed significant stress masking and density loss in the neck of the femur after hip replacement, and electrical stimulation placed in the neck of the femur may resist this density loss to a certain extent. The rate of bone mineral density reduction decreased after the addition of electrical stimulation, indicating that electrical stimulation can have a certain resistance to the density reduction caused by stress shielding, and this result is helpful for the rehabilitation of hip arthroplasty.Keywords
Funding Information
- National Natural Science Foundation of China (12372080)
This publication has 37 references indexed in Scilit:
- Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness—a comparing biomechanical finite element analysisInternational Orthopaedics, 2023
- Bone physiological microenvironment and healing mechanism: Basis for future bone-tissue engineering scaffoldsBioactive Materials, 2021
- New materials for hip and knee joint replacement: What's hip and what's in kneed?Journal of Orthopaedic Research, 2020
- Electrical stimulation in bone tissue engineering treatmentsEuropean Journal of Trauma and Emergency Surgery, 2020
- Effects of pulsed electromagnetic fields and platelet rich plasma in preventing osteoclastogenesis in an in vitro model of osteolysisJournal of Cellular Physiology, 2017
- Up‐regulation of expression of selected genes in human bone cells with specific capacitively coupled electric fieldsJournal of Orthopaedic Research, 2014
- Computational simulation of simultaneous cortical and trabecular bone change in human proximal femur during bone remodelingJournal of Biomechanics, 2010
- Capacitively coupled electric fields accelerate proliferation of osteoblast-like primary cells and increase bone extracellular matrix formation in vitroEuropean Biophysics Journal, 2000
- Formation of osteoclast‐like cells is suppressed by low frequency, low intensity electric fieldsJournal of Orthopaedic Research, 1996
- A physiological approach to the simulation of bone remodeling as a self-organizational control processJournal of Biomechanics, 1994