In vitro evaluation of dissolution behavior for a colon-specific drug delivery system (CODES™) in multi-pH media using United States Pharmacopeia apparatus II and III
Authors:
- 1 February 2002
- journal article
- research article
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 3 (4) , 59-67
Abstract
United States Pharmacopeia dissolution apparatus II (paddle) and III (reciprocating cylinder) coupled with automatic sampling devices and software were used to develop a testing procedure for acquiring release profiles of colon-specific drug delivery system (CODES™) drug formulations in multi-pH media using acetaminophen (APAP) as a model drug. System suitability was examined. Several important instrument parameters and formulation variables were evaluated. Release profiles in artificial gastric fluid (pH 1.2), intestinal fluid (pH 6.8), and pH 5.0 buffer were determined. As expected, the percent release of APAP from coated core tablets was highly pH dependent. A release profile exhibiting a negligible release in pH 1.2 and 6.8 buffers followed by a rapid release in pH 5.0 buffer was established. The drug release in pH 5.0 buffer increased significantly with the increase in the dip or paddle speed but was inversely related to the screen mesh observed at lower dip speeds. It was interesting to note that there was a close similarity (f 2=80.6) between the release profiles at dip speed 5 dpm and paddle speed 100 rpm. In addition, the release rate was reduced significantly with the increase in acid-soluble Eudragit E coating levels, but lactulose loading showed only a negligible effect. In conclusion, the established reciprocating cylinder method at lower agitation rates can give release profiles equivalent to those for the paddle procedure for CODES™ drug pH-gradient release testing. Apparatus III was demonstrated to be more convenient and efficient than apparatus II by providing various programmable options in sampling times, agitation rates, and medium changes, which suggested that the apparatus II approach has better potential for in vitro evaluation of colon-specific drug delivery systems.Keywords
This publication has 24 references indexed in Scilit:
- Evaluation of USP apparatus 3 for dissolution testing of immediate-release productsAAPS PharmSci, 2002
- Unconventional dissolution methodologiesJournal of Pharmaceutical Sciences, 1999
- A pH-dependent colon targeted oral drug delivery system using methacrylic acid copolymersJournal of Controlled Release, 1999
- USP Dissolution Apparatus III (reciprocating cylinder) for screening of guar-based colonic delivery formulationsJournal of Controlled Release, 1997
- Polymers for colon specific drug deliveryJournal of Controlled Release, 1996
- USP Dissolution Apparatus 3 (Reciprocating Cylinder): Instrument Parameter Effects on Drug Release from Sustained Release FormulationsJournal of Pharmaceutical Sciences, 1995
- Approaches and Opportunities in Colon-Specific Drug DeliveryCritical Reviews™ in Therapeutic Drug Carrier Systems, 1995
- Targeting Drugs to the Colon: Delivery Systems for Oral AdministrationJournal of Drug Targeting, 1994
- A New Method of Dissolution In Vitro, the “Bio-Dis” Apparatus: Comparison with the Rotating Bottle Method and In Vitro:ln Vivo CorrelationsJournal of Pharmaceutical Sciences, 1991
- Effects of lactulose and other laxatives on ileal and colonic pH as measured by a radiotelemetry deviceGut, 1974