Grid-Voltage-Oriented Sliding Mode Control for DFIG Under Balanced and Unbalanced Grid Faults
- 2 November 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 9 (3) , 1090-1098
Abstract
Doubly Fed Induction Generators (DFIGs) are widely used in variable-speed wind turbines. Despite the well-accepted performance of DFIGs, these generators are highly sensible to grid faults. Hence, the presence of grid faults must be considered in the design of any control system to be deployed on DFIGs. Sliding Mode Control (SMC) is a useful alternative for electric machinery control since SMC offers fast dynamic response and less sensitivity to parameter variations and disturbances. Additionally, the natural outputs of SMC are discontinuous signals allowing direct switching of power electronic devices. In this work, a grid-voltage-oriented sliding mode control is proposed and tested under low voltage grid faults. Unlike other non-modulated techniques like direct torque control (DTC) there is not a necessity of modifying the controller structure for withstanding low depth voltage dips. For stator natural flux cancellation, the torque and reactive power references are modified to inject a demagnetizing current. Simulation results demonstrate the demagnetization of the natural flux component as well as a robust tracking control under balanced and unbalanced voltage dips.Keywords
Funding Information
- Bi-national Laboratory on Smart Sustainable Energy Management and Technology Training (266632)
This publication has 35 references indexed in Scilit:
- Discussion Aspects of High-Order Sliding Mode ControlIEEE Transactions on Automatic Control, 2015
- Fast Convergence Delayed Signal Cancellation Method for Sequence Component SeparationIEEE Transactions on Power Delivery, 2014
- Second-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancementISA Transactions, 2014
- Review of international grid codes for wind power integration: Diversity, technology and a case for global standardRenewable and Sustainable Energy Reviews, 2012
- Compensation of network voltage unbalance using doubly fed induction generator-based wind farmsIET Renewable Power Generation, 2009
- Control of a Doubly Fed Induction Generator in a Wind Turbine During Grid Fault Ride-ThroughIEEE Transactions on Energy Conversion, 2006
- Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage DipIEEE Transactions on Energy Conversion, 2005
- Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions2005
- Indirect stator flux-oriented output feedback control of a doubly fed induction machineIEEE Transactions on Control Systems Technology, 2003
- Research of stability of double fed induction motor vector control system2002