Inexpensive low-oxygen incubators
- 1 November 2006
- journal article
- research article
- Published by Springer Nature in Nature Protocols
- Vol. 1 (4) , 2088-2090
Abstract
Although the evidence is overwhelming that ambient oxygen is at least somewhat damaging to most normal cells in culture, the expense and effort involved has resulted in few laboratories growing their cells under physiological oxygen conditions. We here describe how to produce, from commercially available plastic wide-mouth jars, very simple gas-tight containers that can be flushed with prepared gas mixtures to produce low-oxygen environments for standard cell culture. This permits any laboratory to easily try the effects of physiological oxygen on their system without the need for dedicated incubators and substantial monetary investments.Keywords
This publication has 6 references indexed in Scilit:
- Developmental differences in the immortalization of lung fibroblasts by telomeraseAging Cell, 2003
- Oxygen sensitivity severely limits the replicative lifespan of murine fibroblastsNature Cell Biology, 2003
- Limitations to oxygen diffusion and equilibration in in vitro cell exposure systems in hyperoxia and hypoxiaAmerican Journal of Physiology-Lung Cellular and Molecular Physiology, 2001
- Telomere dynamics in cancer progression and prevention: fundamental differences in human and mouse telomere biologyNature Medicine, 2000
- Cellular SenescenceCell, 2000
- Low oxygen concentration extends the lifespan of cultured human diploid cellsNature, 1977