Correcting for the heterogeneous boron distribution in a tumor for BNCT dose calculation
Authors:
Open Access
- 21 September 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Abstract
Most treatment planning systems of boron neutron capture therapy perform dose calculations based on the assumption of a homogeneous boron distribution in tumors, which leads to dose distortion due to the difference between the tumor-to-normal tissue ratio (TNR) range measured in positron emission tomography images (PET) and the target delineation in computed tomography images of the treatment plan. The heterogeneous boron distribution in the target of the treatment plan can be obtained by image fusion. This study provides a way to quantify a heterogeneous boron distribution based on PET images. Theoretically, the same mean TNR for dose calculation by homogeneous or heterogeneous boron distribution should get almost the same mean dose. However, slightly different mean doses are found due to the partial volume effect for a small target volume. The wider the boron distribution is, the higher the impact on the dose-volume histogram distribution is. Dose distribution with homogeneous boron distribution may be overestimated in low boron uptake regions by wrong boron concentration and neutron flux depression. To accurately give the tumor prescription dose and achieve better tumor control, for low dose regions of the tumor should be considered more boron neutron capture therapy treatments or combined with other treatment modalities. The heterogeneous boron distribution must be taken into consideration to have an accurate dose estimation. Therefore, the way how medical physicists and clinicians process the TNR in gross tumor volume should be refined, and the method demonstrated in the work provides a good reference.Keywords
All Related Versions
This publication has 28 references indexed in Scilit:
- Boron neutron capture therapy and 18F-labelled borophenylalanine positron emission tomography: A critical and clinical overview of theliteratureApplied Radiation and Isotopes, 2013
- The Photon-Isoeffective Dose in Boron Neutron Capture TherapyRadiation Research, 2012
- Positron Emission Tomography-Computed Tomography Standardized Uptake Values in Clinical Practice and Assessing Response to TherapySeminars in Ultrasound, CT and MRI, 2010
- Feasibility of boron neutron capture therapy (BNCT) for malignant pleural mesothelioma from a viewpoint of dose distribution analysisInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Experimental and computational validation of BDTPS using a heterogeneous boron phantomApplied Radiation and Isotopes, 2004
- Relative biological effectiveness (RBE), quality factor ( Q ), and radiation weighting factor ( w R )Annals of the ICRP, 2003
- Improved treatment planning for boron neutron capture therapy for glioblastoma multiforme using fluorine‐18 labeled boronophenylalanine and positron emission tomographyMedical Physics, 2002
- Boron self-shielding effects on dose delivery of neutron capture therapy using epithermal beam and boronophenylalanineMedical Physics, 1999
- Evaluation of fluorine-18-BPA-fructose for boron neutron capture treatment planning.1997
- Standardized uptake values of FDG: body surface area correction is preferable to body weight correction.1994