Abstract
Summary: We evaluate the suitability of conventional sample preparation and labelling methods for two superresolution techniques, structured illumination microscopy and direct stochastic optical reconstruction microscopy, by a comparison to established confocal laser scanning microscopy. We show that SIM is compatible with standard fixation procedures and immunofluorescence labelling protocols and improves resolution by a factor of two compared to confocal laser scanning microscopy. With direct stochastic optical reconstruction microscopy, fluorophores can theoretically be localized with much higher precision. However, in practice, with indirect immunofluorescence labelling density can be insufficient due to the bulky probes to reveal biological structures with high resolution. Fine structures like single actin fibres are in fact resolved with direct stochastic optical reconstruction microscopy when using small affinity probes, but require proper adjustment of the fixation protocol. Finally, by a direct comparison of immunofluorescent and genetic labelling with fluorescent proteins, we show that target morphology in direct stochastic optical reconstruction microscopy data sets can differ significantly depending on the labelling method and the molecular environment of the target.Keywords
This publication has 33 references indexed in Scilit:
- Correlative multicolor 3D SIM and STORM microscopyBiomedical Optics Express, 2014
- Characterization of Differential Toll‐like Receptor Responses below the Optical Diffraction LimitSmall, 2012
- Evaluation of fluorophores for optimal performance in localization-based super-resolution imagingNature Methods, 2011
- Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent ProbesAngewandte Chemie International Edition, 2008
- Three-dimensional sub–100 nm resolution fluorescence microscopy of thick samplesNature Methods, 2008
- Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction MicroscopyScience, 2008
- Imaging Intracellular Fluorescent Proteins at Nanometer ResolutionScience, 2006
- Saturated patterned excitation microscopy—a concept for optical resolution improvementJournal of the Optical Society of America A, 2002
- Surpassing the lateral resolution limit by a factor of two using structured illumination microscopyJournal of Microscopy, 2000
- Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopyOptics Letters, 1994