Automated infusion of vasoactive and inotropic drugs to control arterial and pulmonary pressures during cardiac surgery
Authors:
- Sebastiaan A. A. P. HoekselSHSebastiaan A. A. P. Hoeksel
- Johannes A. BlomJBJohannes A. Blom
- Jozef R. C. JansenJJJozef R. C. Jansen
- Josephus G. MaessenJMJosephus G. Maessen
- Jan J. SchreuderJSJan J. Schreuder
- 1 December 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 27 (12) , 2792-2798
Abstract
To evaluate the feasibility of a closed-loop system for simultaneous control of systemic arterial and pulmonary artery blood pressures during cardiac surgery. Feasibility study. The cardiac surgery operating room. The performance of the multiple-drug closed-loop system was evaluated during cardiac surgery in 30 patients who required treatment with more than one vasoactive or inotropic drug. A multiple-drug closed-loop system integrated five single-drug blood pressure controllers. Arterial hypertension was controlled using sodium nitroprusside or nitroglycerin, arterial hypotension was controlled using noradrenaline or dobutamine, and pulmonary hypertension was controlled using nitroglycerin. The anesthesiologist selected target pressures and single-drug blood pressure controllers. The multiple-drug closed-loop system had a set of priority rules that automatically activated from the selected single-drug controllers the optimum single-drug controller for each hemodynamic state. Drug infusion rates of the nonactive controllers were kept constant. The initial knowledge that was used to construct the priority rules was obtained from standard anesthetic protocols on perioperative management of cardiac surgical patients. A supervisory computer program defined the actions to be taken in cases of infusion pump problems, invalid pressure measurements, and during unexpected increases and decreases in systemic arterial pressure. The activation of single-drug controllers by the priority rules was accurate and fast. On average, a different single-drug controller was activated once every 7.2 mins. As a measure of variability, the average deviation of mean arterial pressure and mean pulmonary artery pressure from their target values was evaluated and was 8.6 ± 4.0 and 4.4 ± 4.0 mm Hg, respectively, before cardiopulmonary bypass and 8.0 ± 3.6 and 2.4 ± 0.9 mm Hg, respectively, after cardiopulmonary bypass. None of the single-drug controllers showed any signs of unstable response. Closed-loop control of both arterial and pulmonary pressures using multiple drugs is feasible during cardiac surgery.Keywords
This publication has 15 references indexed in Scilit:
- Automated infusion of nitroglycerin to control arterial hypertension during cardiac surgeryIntensive Care Medicine, 1996
- Multiple drug hemodynamic control by means of a supervisory-fuzzy rule-based adaptive control system: validation on a modelIEEE Transactions on Biomedical Engineering, 1995
- Control strategies for arterial blood pressure regulationIEEE Transactions on Biomedical Engineering, 1993
- Multicenter trial of automated nitroprusside infusion for postoperative hypertensionThe Annals of Thoracic Surgery, 1992
- PROPOFOL ACTIVATES THE GABAA RECEPTOR-IONOPHORE COMPLEX IN DISSOCIATED HIPPOCAMPAL NEURONS OF THE RATAnesthesiology, 1992
- Multiple-model adaptive predictive control of mean arterial pressure and cardiac outputIEEE Transactions on Biomedical Engineering, 1992
- Expert control of the arterial blood pressure during surgeryJournal of Clinical Monitoring and Computing, 1991
- Computer control systems and pharmacological drug administration: a surveyJournal of Medical Engineering & Technology, 1990
- Adaptive Multivarable Drug Delivery: Control of Artenal Pressure and Cardiac Output in Anesthetized DogsIEEE Transactions on Biomedical Engineering, 1987
- Automated Treatment of Critically Ill Patients Following OperationAnnals of Surgery, 1968