Three-dimensional non-parametric method for limbus detection
Open Access
- 26 November 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0207710
Abstract
To present a novel non-parametric algorithm for detecting the position of the human eye limbus in three dimensions and a new dynamic method for measuring the full 360° visible iris boundary known as white-to-white distance along the eye horizontal line. The study included 88 participants aged 23 to 65 years (37.7±9.7), 47 females and 41 males. Clinical characteristics, height data and the apex coordinates and 1024×1280 pixel digital images of the eyes were taken by an Eye Surface Profiler and processed by custom-built MATLAB codes. A dynamic light intensity frequency based white-to-white detection process and a novel three-dimensional method for limbus detection is presented. Evidence of significant differences (p<0.001) between nasal-temporal and superior-inferior white-to-white distances in both right and left eyes were found (nasal-temporal direction; 11.74±0.42 mm in right eyes and 11.82±0.47 mm in left eyes & superior-inferior direction; 11.52±0.45 mm in right eyes and 11.55±0.46 mm in left eyes). Average limbus nasal-temporal diameters were 13.64±0.55 mm for right eyes, and 13.74±0.40 mm for left eyes, however the superior-inferior diameters were 13.65±0.54 mm, 13.75±0.38 mm for right and left eyes, respectively. No significant difference in limbus contours has been observed either between the nasal-temporal direction (p = 0.91) and the superior-inferior direction (p = 0.83) or between the right (p = 0.18) and left eyes (p = 0.16). Evidence of tilt towards the nasal-temporal side in the three-dimensional shape of the limbus was found. The right eyes mean limbus contour tilt around the X-axis was -0.3±1.35° however, their mean limbus contour tilt around the Y-axis was 1.76±0.9°. Likewise, the left eyes mean limbus contour tilt around the X-axis was 0.77±1.25° and the mean limbus contour tilt around the Y-axis was -1.54±0.89°. The white-to-white distance in the human eye is significantly larger in the nasal-temporal direction than in the superior-inferior direction. The human limbus diameter was found not to vary significantly in these directions. The 3D measures show that the limbus contour does not lay in one plane and tends to be higher on the nasal-inferior side of the eye.Keywords
Funding Information
- Innovate UK (009521/UVP016)
This publication has 37 references indexed in Scilit:
- Comparative analysis of white-to-white and angle-to-angle distance measurements with partial coherence interferometry and optical coherence tomographyJournal of Cataract & Refractive Surgery, 2010
- Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systemsClinical and Experimental Optometry, 2009
- Relationship between the corneal surface and the anterior segment of the cornea: An Asian perspectiveJournal of Cataract & Refractive Surgery, 2006
- Laser Scanning In Vivo Confocal Microscopy of the Normal Human Corneoscleral LimbusInvestigative Ophthalmology & Visual Science, 2006
- Growth of the cornea from infancy to adolescenceOphthalmic and Physiological Optics, 2005
- Comparison of manual and automated methods to determine horizontal corneal diameterJournal of Cataract & Refractive Surgery, 2004
- Automatic estimation of the corneal limbus in videokeratoscopyIEEE Transactions on Biomedical Engineering, 2002
- Clinical performance and factors affecting the physical fit of a soft toric frequent replacement contact lensClinical and Experimental Optometry, 2002
- The corneo‐limbal ring in normal and keratoconic eyesActa Ophthalmologica, 1988
- A New Method for Measuring the Diameter of the in Vivo Human CorneaOptometry and Vision Science, 1982