An ANN – Constant power generation control for LVRT of grid-connected PVG
Authors:
Open Access
- 23 January 2023
- journal article
- research article
- Published by SAGE Publications in Energy Exploration & Exploitation
- Vol. 41 (3) , 1169-1186
Abstract
This paper discusses an approach low-voltage ride-through control of a boost-converter for a two-stage grid-connected PV system under balanced grid voltage dips (BGVD). A combination of a maximum power point tracking (MPPT) and constant power generation (CPG) to control the boost-converter, respectively, in normal operation mode and BGVD under rapidly changing climatic conditions is proposed. MPPT and CPG commands based on artificial neural network algorithms are developed. Their goal is to maintain the operation of the low-voltage grid-connected photovoltaic system under instantaneously BGVD. This approach ensures a balance between the PV power generation and the injected active power when BGVD appears at the common coupling point (CCP). It permits to regulate the PV power to a specific value, to limit the over current at the CCP and to avoid energy aggregation at the DC-link bus. Simulations of 2.5 kW of a two-stage grid-connected PV system to verify the effectiveness of the command approach are presented.Keywords
This publication has 18 references indexed in Scilit:
- Benchmarking of constant power generation strategies for single-phase grid-connected Photovoltaic systems2016
- Worried about privacy? Let your PV converter cover your electricity consumption fingerprints2015
- Adaptive DC-Link Voltage Control of Two-Stage Photovoltaic Inverter During Low Voltage Ride-Through OperationIEEE Transactions on Power Electronics, 2015
- Renewable Energy Devices and Systems – State-of-the-Art Technology, Research and Development, Challenges and Future TrendsElectric Power Components and Systems, 2015
- FPGA-based implementation of an adaptive P&O MPPT controller for PV applications2014
- Modified Incremental Conductance Algorithm for Photovoltaic System Under Partial Shading Conditions and Load VariationIEEE Transactions on Industrial Electronics, 2014
- On-line optimization of the P&O MPPT method by means of the system identification2013
- Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic InvertersIEEE Transactions on Industry Applications, 2013
- Positive- and negative-sequence control of grid-connected photovoltaic systems under unbalanced voltage conditions2013
- Low voltage ride through control strategy for high-power grid-connected photovoltaic inverter2013