Development of a multipurpose ion source for LC-MS and GC-API MS
- 26 July 2008
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 392 (1-2) , 87-96
Abstract
Over the past decade, multimode ion sources operating at atmospheric pressure (i.e., more than one ionization method is operative in the ion source enclosure) have received considerable interest. Simultaneous operation of different ionization methods targeting different compound classes within one analysis run has several advantages, including enhanced sample throughput and thus significant laboratory cost reductions. Potential drawbacks are enhanced ion suppression and other undesirable effects of the simultaneous operation of ionization methods. In this contribution we present an alternative approach—the development and characterization of a widely applicable, multipurpose ion source operating at atmospheric pressure. The optimized source geometry allows rapid changing from LC-API methods (ESI, APCI, APLI) to GC-API methods (APCI, APLI, DA-APLI) along with the appropriate coupling of chromatographic equipment required. In addition, true multimode operation of the source is demonstrated for LC-ESI/APLI and LC-APCI/APLI.Keywords
This publication has 15 references indexed in Scilit:
- Characterization of non-polar aromatic hydrocarbons in crude oil using atmospheric pressure laser ionization and Fourier transform ion cyclotron resonance mass spectrometry (APLI FT-ICR MS)The Analyst, 2008
- Ultrasensitive Determination of Polycyclic Aromatic Compounds with Atmospheric-Pressure Laser Ionization as an Interface for GC/MSAnalytical Chemistry, 2007
- Electrospray ionization/atmospheric pressure photoionization multimode source for low‐flow liquid chromatography/mass spectrometric analysisRapid Communications in Mass Spectrometry, 2007
- A silica-based monolithic column in capillary HPLC and CEC coupled with ESI-MS or electrospray-atmospheric-pressure laser ionization-MSElectrophoresis, 2005
- Cyclodehydrogenation Reactions to Cyclopentafused Polycyclic Aromatic HydrocarbonsThe Journal of Physical Chemistry A, 2005
- Atmospheric‐pressure laser ionization: a novel ionization method for liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2005
- Combined Electrospray Ionization−Atmospheric Pressure Chemical Ionization Source for Use in High-Throughput LC−MS ApplicationsAnalytical Chemistry, 2003
- Atmospheric Pressure Photoionization: An Ionization Method for Liquid Chromatography−Mass SpectrometryAnalytical Chemistry, 2000
- Evaluation of a dual electrospray ionization/atmospheric pressure chemical ionization source at low flow rates (∼50 µL/min) for the analysis of both highly and weakly polar compoundsJournal of the American Society for Mass Spectrometry, 1998
- Bewertung und Vergleich von AnalysenverfahrenAnalytical and Bioanalytical Chemistry, 1956