Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
- 5 November 2009
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 20 (5) , 1118-1123
Abstract
Objectives Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. Methods We studied 41 DSCT in consecutive patients with a heart rate >65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Results Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Conclusion Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.Keywords
This publication has 27 references indexed in Scilit:
- Diagnostic Accuracy of Dual-Source Computed Tomography in the Diagnosis of Coronary Artery DiseaseInvestigative Radiology, 2007
- Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate VariabilityAmerican Journal of Roentgenology, 2007
- Image Quality and Reconstruction Intervals of Dual-Source CT Coronary AngiographyInvestigative Radiology, 2007
- Dual-source CT cardiac imaging: initial experienceEuropean Radiology, 2006
- Image Quality, Motion Artifacts, and Reconstruction Timing of 64-Slice Coronary Computed Tomography Angiography With 0.33-Second Rotation SpeedInvestigative Radiology, 2006
- Contrast-enhanced coronary artery visualization by dual-source computed tomography—Initial experienceEuropean Journal of Radiology, 2006
- Do Segmented Reconstruction Algorithms for Cardiac Multi-Slice Computed Tomography Improve Image Quality?Herz, 2003
- Coronary Artery Motion During the Cardiac Cycle and Optimal ECG Triggering for Coronary Artery ImagingInvestigative Radiology, 2001
- Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR AngiographyRadiology, 1999
- The phases of the cardiac cycleAmerican Heart Journal, 1972