Electrochemically Induced Free‐Radical Polymerization for the Fabrication of Amperometric Glucose Biosensors
Authors:
- 16 September 2010
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 22 (20) , 2366-2375
Abstract
Electrochemically induced free radical polymerization was employed for the fabrication of amperometric glucose biosensors. Based on the electrochemical reduction of persulfate anion, an ultrathin poly(acrylic acid) (PAA) hydrogel coating was generated on both the bare and glucose oxidase (GOD) crosslinked platinum electrodes in a neutral phosphate buffer solution under a low ionic strength condition. This electrosynthetic approach offers a flexible and controllable way to prepare functional coatings for biosensors under a wide range of highly biocompatible conditions, significantly different from other electropolymerization technologies that usually cause the enzyme deactivation. Negatively charged PAA hydrogel coating not only results in a biosensor with good permselectivity and long‐term stability, but also remarkably enhances its sensitivity by improving the oxygen recycle supply and the enzyme activity. Combined with a simple drop‐evaporation procedure to control the GOD loading, the present method offers a versatile and biocompatible way for fabricating highly sensitive biosensor.Keywords
This publication has 37 references indexed in Scilit:
- Electrochemical SensorsAnalytical Chemistry, 2008
- Electrochemical nanobiosensorsSensors and Actuators B: Chemical, 2007
- Amperometric Biosensors Based on Choline Oxidase Entrapped in Polyacrylamide MicrogelsElectroanalysis, 2007
- Prospects of conducting polymers in biosensorsAnalytica Chimica Acta, 2006
- Protease Amperometric SensorAnalytical Chemistry, 2006
- Formation of Surface-Attached Responsive Gel Layers via Electrochemically Induced Free-Radical PolymerizationLangmuir, 2006
- High stability amperometric biosensor based on enzyme entrapment in microgelsTalanta, 2005
- Electrochemical polymerization of acrylics on stainless steel cathodesJournal of Applied Polymer Science, 2002
- Electrodeposition of Redox Polymers and Co-Electrodeposition of Enzymes by Coordinative Crosslinking This research was supported by the Welch Foundation and by the US Army Research Laboratory.Angewandte Chemie International Edition, 2002
- Polymerization behavior and distribution of carboxyl groups in preparation of soap-free carboxylated polystyrene latexesJournal of Applied Polymer Science, 1977