Changes of periprosthetic bone density after a cementless short hip stem: a clinical and radiological analysis
- 11 June 2014
- journal article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (10) , 2045-2050
Abstract
The purpose of this study was to examine the concept of proximal load initiation of a total short-stemmed hip arthroplasty (Metha® BBraun, Aesculap, Tuttlingen, Germany) on the basis of bone variations by means of osteodensitometric dual energy X-ray absorptiometry and radiologic measurements. After power analysis 40 patients were included in this study. DXA examination, radiological and clinical follow-up was performed pre-operatively and postoperatively. Socio-demographic relevancies of bone progression and radiological changes were raised epidemiologically and clinically. Improvement of the Harris hip score from 54.7 points preoperative to 96.7 points postoperative was detected (p < 0.01). Loss of summarized overall net average bone mass density (netavg BMD) could only be manifested after six months compared to the netavg BMD of the postoperative measurement (p < 0.01). After six and 12 months BMD atrophy was shown mainly in regions of interest (ROI) 1, 4 and 7. Positive correlations between changes of BMD and age, male sex and BMI were detectable. No stem had to be revised. The Metha® implant shows excellent osseointegration at the coated area of the stem without factors of aseptic loosening in the short term. This study shows that parameters like age, sex and BMI influence BMD progression and stress shielding. Metha® implant shows excellent results especially in young patients with good bone stock.Keywords
This publication has 23 references indexed in Scilit:
- Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry studyInternational Orthopaedics, 2011
- A randomized study using DXA and RSA in 38 patients followed for 5 yearsActa Orthopaedica, 2010
- Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up studyInternational Orthopaedics, 2009
- 8-Jahres-Resultate der Schenkelhalsprothese ESKA‐CUTZeitschrift für Orthopädie und Unfallchirurgie, 2009
- A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: design rationals and study design of an international clinical trialBMC Musculoskeletal Disorders, 2008
- Langfristiger Einfluss der anatomisch angepassten spongiösen Endoprothese auf den periprothetischen KnochenZeitschrift für Orthopädie und ihre Grenzgebiete, 2006
- Vorteile der minimalinvasiven Implantation von Hüfttotalendoprothesen in der frühen postoperativen RehabilitationsphaseZeitschrift für Orthopädie und ihre Grenzgebiete, 2004
- Wertigkeit und Reproduzierbarkeit osteodensitometrischer DEXA-Messungen nach HüfttotalendoprothesenimplantationZeitschrift für Orthopädie und ihre Grenzgebiete, 1997
- Dual X-ray absorptiometry for the evaluation of bone density from the proximal femur after total hip arthroplasty: Analysis protocols and reproducibilityCalcified Tissue International, 1993
- Die Lehre von der functionellen KnochengestaltVirchows Archiv, 1899