Custom-designed Small Animal focal iRradiation Jig (SARJ): design, manufacture and dosimetric evaluation
Open Access
- 1 November 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 2 (1) , 20190045
Abstract
Objective: Preclinical animal models allow testing and refinement of novel therapeutic strategies. The most common preclinical animal irradiators are fixed source cabinet irradiators, which are vastly inferior to clinical linear accelerators capable of delivering highly conformal and precise treatments. The purpose of this study was to design, manufacture and test an irradiation jig (small animal focal irradiation jig, SARJ) that would enable focal irradiation of subcutaneous tumours in a standard fixed source cabinet irradiator. Methods and materials: A lead shielded SARJ was designed to rotate animal holders about the longitudinal axis and slide vertically from the base plate. Radiation dosimetry was undertaken using the built-in ion chamber and GAFChromic RTQA2 and EBT-XD films. Treatment effectiveness was determined by irradiating mice with subcutaneous melanoma lesions using a dose of 36 Gy in three fractions (12 Gy x 3) over three consecutive days. Results: The SARJ was tested for X-ray shielding effectiveness, verification of dose rate, total dose delivered to tumour and dose uniformity. Accurate and uniform delivery of X-ray dose was achieved. X-ray doses were limited to the tumour site when animal holders were rotated around their longitudinal axis to 15o and 195o, allowing sequential dose delivery using parallel-opposed tangential beams. Irradiation of subcutaneous melanoma tumour established on the flanks of mice showed regression. Conclusion: SARJ enabled delivery of tangential parallel-opposed radiation beams to subcutaneous tumours in up to five mice simultaneously. SARJ allowed high throughput testing of clinically relevant dose delivery using a standard cabinet-style fixed source irradiator. Advances in knowledge: A custom designed jig has been manufactured to fit into conventional cabinet irradiators and is dosimetrically validated to deliver clinically relevant dose distributions to subcutaneous tumours in mice for preclinical studies.Keywords
This publication has 28 references indexed in Scilit:
- Preclinical mouse solid tumour models: status quo, challenges and perspectivesNature Reviews Cancer, 2017
- The immune contexture in cancer prognosis and treatmentNature Reviews Clinical Oncology, 2017
- Tumour and normal tissue radiobiology in mouse models: how close are mice to mini-humans?British Journal of Radiology, 2017
- Reference radiochromic film dosimetry: Review of technical aspectsPhysica Medica, 2016
- The Relevance of Dosimetry in Animal Models of Cochlear IrradiationOtology & Neurotology, 2014
- Safety and Otoprotection of Metformin in Radiation‐Induced Sensorineural Hearing Loss in the Guinea PigOtolaryngology–Head and Neck Surgery, 2014
- Development and validation of a treatment planning system for small animal radiotherapy: SmART-PlanRadiotherapy and Oncology, 2013
- Characterization of image quality and image‐guidance performance of a preclinical microirradiatorMedical Physics, 2011
- Precise radiochromic film dosimetry using a flat-bed document scannerMedical Physics, 2005
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001