Reproducibility of the Dobutamine‐Atropine Echocardiography Stress Test
Authors:
- Paolo BellottiPBPaolo Bellotti
- Paolo M. FiorettiPFPaolo M. Fioretti
- Tamas ForsterTFTamas Forster
- ALBERT J. McNEILLAMALBERT J. McNEILL
- El‐Said M. EL SaidESEl‐Said M. EL Said
- Alessandro SalustriASAlessandro Salustri
- Jos R.T.C. RoelandtJRJos R.T.C. Roelandt
- 1 January 1993
- journal article
- Published by Wiley in Echocardiography
- Vol. 10 (1) , 93-97
Abstract
To assess the reproducibility of dobutamine‐atropine echocardiography testing, two studies (1 to 20 days apart [mean 3.3 days]) were performed in 23 patients with stable effort angina pectoris or chest pain. During the study, 20 (87%) patients were receiving beta blockers alone or combined with nitrates or calcium antagonists. Dobutamine was infused at doses of 10 μg/kg per minute every 3 minutes up to a maximum of 40 μg/kg per minute and this maximal dose was continued for 6 minutes. In patients not achieving 85% predicted maximal heart rate or myocardial ischemia, atropine (0.25–1 mg) was added and dobutamine continued for another 3 minutes, until either an adequate heart rate was achieved or the test was considered positive. During dobutamine infusion, electrocardiographic, echocardiographic, and blood pressure monitoring were obtained in each patient. Side effects including tremor, nausea, palpitation, dizziness, headache, and nonsustained ventricular tachycardia occurred in three patients. The same symptoms, but no ventricular tachycardia, developed during the same stage of the second test. Angina pectoris (eight patients), electrocardiographic changes (six patients), and ischemic wall‐motion abnormalities (six patients) were observed at the same stage of the two tests. The mean values of heart rate, blood pressure, and rate‐pressure product were comparable for each stage in duplicate tests. Our data show that pharmacological stress echocardiography using dobutamine‐atropine has good reproducibility and provides a useful tool for assessing disease progression and the effects of therapeutic interventions in patients with coronary artery disease.Keywords
This publication has 12 references indexed in Scilit:
- Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dobutamine stress echocardiographyThe American Journal of Cardiology, 1992
- Echocardiographic detection of coronary artery disease during dobutamine infusion.Circulation, 1991
- Exercise echocardiography and technetium-99m MIBI single-photon emission computed tomography in the detection of coronary artery diseaseThe American Journal of Cardiology, 1991
- Prognostic importance of dipyridamole-echocardiography test in coronary artery disease.Circulation, 1989
- High dose dipyridamole echocardiography early after uncomplicated acute myocardial infarction: Correlation with exercise testing and coronary angiographyJACC, 1989
- Short-term reproducibility of dipyridamole-echocardiography testClinical Cardiology, 1987
- Predicting the extent and location of coronary artery disease in acute myocardial infarction by echocardiography during dobutamine infusionThe American Journal of Cardiology, 1986
- Variability of results during repeat exercise stress testing in patients with stable angina pectoris: Role of dynamic coronary flow reserveAmerican Heart Journal, 1986
- Repeat treadmill exercise testing: Variability of results in patients with angina pectorisAmerican Heart Journal, 1984
- The Mechanism of Action of DobutamineAnnals of Internal Medicine, 1984