Development of microfabricated magnetic actuators for removing cellular occlusion
Authors:
- 28 April 2011
- journal article
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 21 (5) , 054006
Abstract
Here we report on the development of torsional magnetic microactuators for displacing biological materials in implantable catheters. Static and dynamic behaviors of the devices were characterized in air and in fluid using optical experimental methods. The devices were capable of achieving large deflections (>60°) and had resonant frequencies that ranged from 70 Hz to 1.5 kHz in fluid. The effect of long-term actuation (>2.5 · 108 cycles) was quantified using resonant shift as the metric (Δf < 2%). Cell-clearing capabilities of the devices were evaluated by examining the effect of actuation on a layer of aggressively growing adherent cells. On average, actuated microdevices removed 37.4% of the adherent cell layer grown over the actuator surface. The effect of actuation time, deflection angle, and beam geometry were evaluated. The experimental results indicate that physical removal of adherent cells at the microscale is feasible using magnetic microactuation.Keywords
This publication has 42 references indexed in Scilit:
- Intraventricular infusion of hyperosmolar dextran induces hydrocephalus: a novel animal model of hydrocephalusFluids and Barriers of the CNS, 2009
- Are we implanting catheters that facilitate shunt failure?Fluids and Barriers of the CNS, 2009
- A novel microdevice for the treatment of hydrocephalus: design and fabrication of an array of microvalves and microneedlesMicrosystem Technologies, 2007
- Nano-scale fatigue study of LPCVD silicon nitride thin films using a mechanical-amplifier actuatorJournal of Micromechanics and Microengineering, 2007
- Hydromer-coated catheters to prevent shunt infection?Journal of Neurosurgery, 2005
- A multicenter prospective cohort study of the Strata valve for the management of hydrocephalus in pediatric patientsJournal of neurosurgery. Pediatrics, 2005
- A Randomized, Controlled Study of a Programmable Shunt Valve versus a Conventional Valve for Patients with HydrocephalusNeurosurgery, 1999
- A New Ventricular Catheter for the Prevention and Treatment of Proximal Obstruction in Cerebrospinal Fluid ShuntsNeurosurgery, 1994
- Clinical-Pathological analysis of failed central nervous system fluid shuntsJournal of Biomedical Materials Research, 1989
- Multiflanged ventricular Portnoy catheter for hydrocephalus shuntsActa Neurochirurgica, 1976