Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation
Authors:
- Louis SibilleLSLouis Sibille
- Fayçal Ben BouallegueFBFayçal Ben Bouallegue
- Aurélie BourdonABAurélie Bourdon
- Antoine MicheauAMAntoine Micheau
- Hélène Vernhet-KovacsikHVHélène Vernhet-Kovacsik
- Denis Mariano-GoulartDMDenis Mariano-Goulart
- 1 February 2011
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 32 (2) , 121-128
Abstract
Gated blood-pool single-photon emission computed tomography (GBPS) was compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular (LV) and right ventricular (RV) ejection fractions (EF) and volumes [end-diastolic volume (EDV) or end-systolic volume (ESV)] in a mixed population. Thirty patients (70% men; mean age: 61±14 years) referred for various symptoms or heart diseases, predominantly ischemic, were included. GBPS data were analyzed using segmentation software described earlier based on the watershed algorithm. CMR images were acquired for both ventricles at the same time using a steady-state-free precession sequence and short-axis views. No compensation for papillary muscles was used. LVEF and RVEF and volumes were assessed with GBPS and CMR and were compared. LVEF and volumes were correlated (P<0.001). The difference in LVEF between GBPS and CMR was not significant (P=0.063). The limits of agreement were close for LVEF (-11 to 15%) and wider for LV volumes (-82 to 11 ml for EDV and -52 to 15 ml for ESV), with higher volume values obtained with CMR (mean differences of 36±24 ml for EDV and 19±17 ml for ESV). The RVEF and volumes assessed by GBPS and CMR were correlated (P<0.001). The difference in RVESV between GBPS or CMR was not significant (P=0.136). The limits of agreement were relatively close for all RV parameters (-15 to 8% for EF; -44 to 22 ml for EDV, and -25 to 21 ml for ESV). In 24 patients without valvulopathy or shunt, the difference between LV stroke volume and RV stroke volume was lower with GBPS than with CMR (9±14 ml and 18±13 ml, respectively, with P=0.027). GBPS is a simple and widely available technique that can assess both LVEF and RVEF, and volumes with slight differences compared with CMR.Keywords
This publication has 36 references indexed in Scilit:
- Comparison of the reproducibility of quantitative cardiac left ventricular assessments in healthy volunteers using different MRI scanners: A multicenter simulationJournal of Magnetic Resonance Imaging, 2008
- MRI comparison of quantitative left ventricular structure, function and measurement reproducibility in patient cohorts with a range of clinically distinct cardiac conditionsThe International Journal of Cardiovascular Imaging, 2008
- Cardiac MRI: accuracy of simultaneous measurement of left and right ventricular parameters using three different sequencesClinical Physiology and Functional Imaging, 2007
- Natural History of Asymptomatic Left Ventricular Systolic Dysfunction in the CommunityCirculation, 2003
- Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failureJACC, 2001
- Limited performance of quantitative assessment of myocardial function by thallium-201 gated myocardial single-photon emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2000
- Incremental Prognostic Value of Post-Stress Left Ventricular Ejection Fraction and Volume by Gated Myocardial Perfusion Single Photon Emission Computed TomographyCirculation, 1999
- Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds:application to the determination of right and left ejection fractionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1998
- Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardium: Echocardiographic validationJournal of Nuclear Cardiology, 1998
- Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.Circulation, 1987