Fabrication of Microfluidic Manifold by Precision Extrusion Deposition and Replica Molding for Cell-Laden Device
- 27 October 2015
- journal article
- Published by ASME International in Journal of Manufacturing Science and Engineering
- Vol. 138 (4) , 041007
Abstract
A PED (precision extrusion deposition)/replica molding process enables scaffold guided tissue engineering of a heterocellular microfluidic device. We investigate two types of cell-laden devices: the first with a 3D microfluidic manifold fully embedded in a PDMS (polydimethylsiloxane) substrate and the second a channel network on the surface of the PDMS substrate for cell printing directly into device channels. Fully embedded networks are leak-resistant with simplified construction methods. Channels exposed to the surface are used as mold to hold bioprinted cell-laden matrix for controlled cell placement throughout the network from inlet to outlet. The result is a 3D cell-laden microfluidic device with improved leak-resistance (up to 2.0 mL/min), pervasive diffusion and control of internal architecture.Keywords
This publication has 56 references indexed in Scilit:
- A Survey of Methods for the Evaluation of Tissue Engineering Scaffold PermeabilityAnnals of Biomedical Engineering, 2013
- A microfluidic hepatic coculture platform for cell-based drug metabolism studiesBiochemical Pharmacology, 2010
- Cofabrication: A Strategy for Building Multicomponent MicrosystemsAccounts of Chemical Research, 2010
- Bioprinting Endothelial Cells With Alginate for 3D Tissue ConstructsJournal of Biomechanical Engineering, 2009
- Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer CellsPLOS ONE, 2009
- Microfluidic system for formation of PC-3 prostate cancer co-culture spheroidsBiomaterials, 2009
- Transport‐mediated angiogenesis in 3D epithelial cocultureThe FASEB Journal, 2009
- A new tool for probing of cell–cell communication: human embryonic germ cells inducing apoptosis of SKOV3 ovarian cancer cells on a microfluidic chipBiotechnology Letters, 2008
- Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/NanosystemsBiomedical Microdevices, 2005
- Key factors in the rising cost of new drug discovery and developmentNature Reviews Drug Discovery, 2004