Effect of Tilt Angle on Subcritical/Supercritical Carbon Dioxide-Based Natural Circulation Loop With Isothermal Source and Sink
- 11 November 2015
- journal article
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 8 (1) , 011007
Abstract
In recent years, a growing popularity of carbon dioxide (CO2) as a secondary fluid has been witnessed in both forced as well as in natural circulation loops (NCLs). This may be attributed to the favorable thermophysical properties of CO2 in addition to the environmental benignity of the fluid. However, an extensive literature review shows that studies on CO2-based NCLs are very limited. Also, most of the studies on NCLs do not consider the three-dimensional variation of the field variables. In the present work, three-dimensional computational fluid dynamics (CFD) models of a NCL with isothermal source and sink have been developed to study the effect of tilt angle in different planes. Studies have been carried out employing subcritical (liquid and vapor) as well as supercritical phase of CO2 as loop fluid at different operating pressures and temperatures. Results are obtained for a range of tilt angles of the loop, and a significant effect is observed on heat transfer, mass flow rate, and stability of the loop. It was also found that changing the orientation of the loop could be an elegant and effective solution to the flow instability problem of NCLs.Keywords
This publication has 25 references indexed in Scilit:
- On the suitability of carbon dioxide in forced circulation-type secondary loopsInternational Journal of Low-Carbon Technologies, 2012
- Simulation of Heat Transfer and System Behavior in a Supercritical CO2 Based Thermosyphon: Effect of Pipe DiameterJournal of Heat Transfer, 2011
- Computational-fluid-dynamics study of a Kenics static mixer as a heat exchanger for supercritical carbon dioxideThe Journal of Supercritical Fluids, 2010
- Effect of heat transfer on the instabilities and transitions of supercritical CO2 flow in a natural circulation loopInternational Journal of Heat and Mass Transfer, 2010
- Carbon dioxide heat pipe in conjunction with a ground source heat pump (GSHP)Applied Thermal Engineering, 2008
- Numerical analysis of supercritical flow instabilities in a natural circulation loopNuclear Engineering and Design, 2008
- Transient and stability analysis in single-phase natural circulationAnnals of Nuclear Energy, 2004
- Open-Loop Thermosyphons with Geological ApplicationsJournal of Heat Transfer, 1979
- Thermosyphon Models for Downhole Heat Exchanger Applications in Shallow Geothermal SystemsJournal of Heat Transfer, 1978
- On the oscillatory instability of a differentially heated fluid loopJournal of Fluid Mechanics, 1967