Reduction of voxel bleeding in highly accelerated parallel 1H MRSI by direct control of the spatial response function
Open Access
- 28 February 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 469-480
Abstract
Purpose: To substantially improve spatial localization in magnetic resonance spectroscopic imaging (MRSI) accelerated by parallel imaging. This is important in order to make MRSI more reliable as a tool for clinical applications.Methods: The sensitivity encoding acceleration technique with spatial overdiscretization is applied for the reconstruction of parallel MRSI. In addition, the spatial response function is optimized by minimizing its deviation from a previously chosen target function. This modified minimum‐norm sensitivity encoding‐MRSI reconstruction approach is applied in this article for in vivo pulse‐acquire MRSI of human brain at 7T with simulated acceleration factors of 2, 4, and 9 as well as actual 4‐fold accelerated MRSI.Results: The sidelobes of the spatial response function are significantly suppressed, which reduces far‐reaching voxel bleeding. At the same time, the major enlargement of the effective voxel size, which would be introduced by conventional k‐space apodization methods, is largely avoided. Regularization allows for a practical trade‐off between noise minimization, effective voxel size, and unaliasing. Although not aiming at increasing the nominal spatial resolution, a better spatial specificity is achieved.Conclusion: Simultaneous suppression of short‐ and far‐reaching voxel bleeding in MRSI is analyzed and reconstruction of highly accelerated parallel in vivo MRSI is demonstrated. Magn Reson Med 73:469–480, 2015. © 2014 Wiley Periodicals, Inc.Keywords
Funding Information
- Swiss National Competence Center for Biomedical Imaging (NCCBI)
This publication has 21 references indexed in Scilit:
- Superresolution parallel magnetic resonance imaging: Application to functional and spectroscopic imagingNeuroImage, 2009
- Slice‐selective FID acquisition, localized by outer volume suppression (FIDLOVS) for 1H‐MRSI of the human brain at 7 T with minimal signal lossNMR in Biomedicine, 2009
- Accelerated short‐TE 3D proton echo‐planar spectroscopic imaging using 2D‐SENSE with a 32‐channel array coilMagnetic Resonance in Medicine, 2007
- Cardiac SSFP imaging at 3 TeslaMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- Fast MRI data acquisition using multiple detectorsMagnetic Resonance in Medicine, 1988
- Spatial Localization in NMR Spectroscopy in VivoAnnals of the New York Academy of Sciences, 1987
- Localized proton spectroscopy using stimulated echoesJournal of Magnetic Resonance (1969), 1987