Abstract
A cyclic voltammetry study is one of electro analytical chemistry methods which able to study the corrosion of material. In this research, the cyclic voltammetry has been carried out in order to determine the voltage range that contributes to the initiation of the corrosion on the surface of stainless steel in the acidic thiourea solution. In this study, the knowledge of corrosion on stainless steel is useful in the optimisation process for gold recovery from electronic waste based on electrodeposition technique. Since stainless steel material has been used as both anode and cathode in the experimental setup, under certain applied voltage, corrosion might occur and hinder the gold recovery process by damaging the electrodes. With the aid of cyclic voltammetry study, the suitable applied voltage for electrodeposition process has been investigated and found to be approximately 1.4 V for two-electrode setup for a system with sulfuric acid concentration of 0.1 M in the presence of 0.1 M thiourea. The data obtained can be used as a basis to determine a suitable pre-set applied voltage in the electrodeposition process such that corrosion on the electrodes can be avoided.Keywords
This publication has 10 references indexed in Scilit:
- A Conceptual Reactor Design Based on Combination of Pressure Leaching - Electrochemical Deposition Techniques for Study of Gold Recovery from e-WasteAdvanced Materials Research, 2015
- Electrochemical Behaviour of AISI 316 Austenitic Stainless Steel in Acidic Media Containing Chloride IonsInternational Journal of Electrochemical Science, 2011
- The interaction of thiourea and formamidine disulfide in the dissolution of gold in sulfuric acid solutionsMinerals Engineering, 2010
- EFFECT OF THIOUREA CONCENTRATION ON THE ELECTROCHEMICAL BEHAVIOR OF GOLD AND COPPER ELECTRODES IN PRESENCE AND ABSENCE OF Cu(II) IONSJournal of the Chilean Chemical Society, 2009
- Corrosion and Corrosion Control2008
- Anodic behavior of gold in acid thiourea solutions: A cyclic voltammetry and quartz microgravimetry studyRussian Journal of Electrochemistry, 2006
- Alternatives to cyanide in the gold mining industry: what prospects for the future?Journal of Cleaner Production, 2006
- Electrochemical processes at gold∣thiourea-containing aqueous acid solution interfacesJournal of Electroanalytical Chemistry, 2003
- Electrochemical Oxidation of Gold and Thiourea in Acidic Thiourea SolutionsJournal of the Electrochemical Society, 2001
- Conversion constants for redox potentials measured versus different reference electrodes in acetonitrile solutions at 25°CInorganica Chimica Acta, 2000