An Energy Efficient ECG Signal Processor Detecting Cardiovascular Diseases on Smartphone
- 26 September 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 11 (2) , 314-323
Abstract
A novel disease diagnostic algorithm for ECG signal processing based on forward search is implemented in Application Specific Integrated Circuit (ASIC) for cardiovascular disease diagnosis on smartphone. An ASIC is fabricated using 130-nm CMOS low leakage process technology. The area of our PQRST ASIC is 1.21 mm2. The energy dissipation of PQRST ASIC is 96 pJ with a supply voltage of 0.9 V. The outputs from the ASIC are fed to an Android application that generates diagnostic report and can be sent to a cardiologist via email. The ASIC and Android application are verified for the detection of bundle branch block, hypertrophy, arrhythmia and myocardial infarction using Physionet PTB diagnostic ECG database. The failed detection rate is 0.69%, 0.69%, 0.34% and 1.72% for bundle branch block, hypertrophy, arrhythmia and myocardial infarction respectively. The AV block is detected in all the three patients in the Physionet St. Petersburg arrhythmia database. Our proposed ASIC together with our Android application is the most suitable for an energy efficient wearable cardiovascular disease detection system.Keywords
This publication has 22 references indexed in Scilit:
- A Wearable Healthcare System With a 13.7 $\mu$ A Noise Tolerant ECG ProcessorIEEE Transactions on Biomedical Circuits and Systems, 2014
- An Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia MonitoringIEEE Journal of Solid-State Circuits, 2014
- A 58 nW ECG ASIC With Motion-Tolerant Heartbeat Timing Extraction for Wearable Cardiovascular MonitoringIEEE Transactions on Biomedical Circuits and Systems, 2014
- A 457 nW Near-Threshold Cognitive Multi-Functional ECG Processor for Long-Term Cardiac MonitoringIEEE Journal of Solid-State Circuits, 2014
- A Level-Crossing Based QRS-Detection Algorithm for Wearable ECG SensorsIEEE Journal of Biomedical and Health Informatics, 2014
- An optimized DSP implementation of adaptive filtering and ICA for motion artifact reduction in ambulatory ECG monitoring2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2012
- A Wavelet-Based ECG Delineator: Evaluation on Standard DatabasesIEEE Transactions on Biomedical Engineering, 2004
- Open source ECG analysis2003
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Automatic Detection of Wave Boundaries in Multilead ECG Signals: Validation with the CSE DatabaseComputers and Biomedical Research, 1994