FairEmbo Concept for Arterial Embolizations: In Vivo Feasibility and Safety Study with Suture-Based Microparticles Compared with Microspheres
- 25 October 2020
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (4) , 625-632
Abstract
Purpose Microspheres are effective embolic agents, especially for the management of bleeding and oncologic lesions. The first FairEmbo study reported the effectiveness of embolization using suture fragments. The effectiveness and safety of arterial embolization with suture-based microparticles (SBM) were assessed in a swine model. Materials and Methods In this ethical-approved animal study, a polar artery in each kidney was embolized in four swine: one side with hand-cut non-absorbable SBM (Flexocrin 2®) and the contralateral side with Embozene® 900 for comparison. Swine were followed for 3 months (M3) to evaluate the effectiveness and the safety of SBM. Follow-up protocol included clinical monitoring, computed tomography (CT) control and digital subtraction angiography (DSA), followed by histological analyses. The SBM confection parameters were evaluated by automatic microscopic sizer. RStudio software and Mann–Whitney test (significance at P < 0.05) were used for statistics. Results The average size of SBM was 1002 μm (SD = 258). All targets were effectively embolized by SBM with an angiogram defect estimated at 45.6% (95% CI [35.9–55.2]), compared to 40.5% (95% CI [30.6–55.5]) for Embozene® group (P = 0.342). The average duration of SBM embolization procedure was significantly increased compared to Embozene® embolization (1202 s versus 222 s, P = 0.029). There were no statistical differences in M3 DSA and CT for SBM and Embozene®, with persistence of partial arterial occlusion and atrophic embolized area. No postoperative complications were observed on clinical and CT controls. Conclusion This experimental study suggests that embolization with SBM is feasible, safe and effective in short- and medium-term follow-up as compared to microspheres.Keywords
This publication has 21 references indexed in Scilit:
- Global, regional, and national incidence, prevalence, and years lived with disability for 301 acute and chronic diseases and injuries in 188 countries, 1990–2013: a systematic analysis for the Global Burden of Disease Study 2013The Lancet, 2015
- Global causes of maternal death: a WHO systematic analysisThe Lancet Global Health, 2014
- In-vitro thrombogenicity assessment of polymer filament modified and native platinum embolic coilsJournal of the Neurological Sciences, 2014
- Transcatheter arterial embolization as therapy of renal angiomyolipomas: The evolution in 15 years of experienceEuropean Journal of Radiology, 2012
- Comparison of porcine and human coagulation by thrombelastometryThrombosis Research, 2011
- Swine as Models in Biomedical Research and Toxicology TestingVeterinary Pathology, 2011
- Infections After Endovascular Coil EmbolizationJournal of Endovascular Therapy, 2007
- Infections Related to Coils Used for Embolization of Arteries: Review of the Published EvidenceJournal of Vascular and Interventional Radiology, 2007
- Polyvinyl Alcohol Particles and Tris-acryl Gelatin Microspheres for Uterine Artery Embolization for Leiomyomas: Results of a Randomized Comparative StudyJournal of Vascular and Interventional Radiology, 2004
- Histopathologic Appearance of Arterial Occlusions with Hydrogel and Polyvinyl Alcohol Embolic Material in Domestic SwineJournal of Vascular and Interventional Radiology, 1996