Early lung absorption profile of non‐CFC salbutamol via small and large volume plastic spacer devices
Authors:
- 1 July 1998
- journal article
- clinical trial
- Published by Wiley in British Journal of Clinical Pharmacology
- Vol. 46 (1) , 45-48
Abstract
Aims To evaluate the lung dose of a non‐CFC salbutamol metered dose inhaler (MDI) formulation via three commonly used plastic spacer devices, of both large and small volume, compared with the MDI used on its own. Methods Ten healthy volunteers were studied in a randomized single (investigator) blind crossover design. Single 1200 μg nominal doses of salbutamol from a non‐CFC MDI (Airomir), as 12 sequential 100 μg puffs over 6 min, were delivered from the MDI alone and via two large volume spacer devices (Nebuhaler, Volumatic), and a small volume spacer (Aerochamber). All spacers were prewashed prior to each study day and mouth rinsing was performed after each drug sequence. Plasma salbutamol was measured at 5, 10, 15 and 20 min, with calculation of maximum (Cmax ) and average (Cav ) concentrations. This lung dose was assessed using the early lung absorption profile of salbutamol in the first 20 min after inhalation. Results Both of the large volume spacers, the Nebuhaler and the Volumatic, delivered significantly more salbutamol than the MDI alone. For Cav this amounted to a 2.07‐fold difference (95% CI 1.48–2.90) between Nebuhaler vs MDI, and a 1.49‐fold difference (95%CI 1.19–1.87) between Volumatic vs MDI. The Nebuhaler also produced greater deposition than either the Volumatic or the Aerochamber spacers; Nebuhaler vs Volumatic: 1.39‐fold difference (95% CI 1.09–1.76), Nebuhaler vs Aerochamber: 1.63‐fold difference (95% CI 1.20–2.21). There were no significant differences between the Aerochamber and the MDI alone. Conclusions Using the early lung absorption profile, for administration of the same nominal dose, both of the large volume spacers (Nebuhaler and Volumatic) but not the small volume spacer (Aerochamber) delivered significantly more salbutamol than the MDI alone. The Nebuhaler also produced greater delivery than either the Volumatic or the Aerochamber spacer devices. Our results show that whilst lung delivery of non‐CFC salbutamol MDI is improved by the use of a plastic spacer, there may be appreciable differences in performance, particularly between large and small volume devices.Keywords
This publication has 18 references indexed in Scilit:
- Pharmacokinetics of inhaled drugsBritish Journal of Clinical Pharmacology, 1996
- Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device.Thorax, 1996
- Inhalational drug delivery from seven different spacer devices.Thorax, 1996
- Lung bioavailability of generic and innovator salbutamol MDIs.Thorax, 1996
- Lung bioavailability of chlorofluorocarbon free, dry powder and chlorofluorocarbon containing formulations of salbutamolBritish Journal of Clinical Pharmacology, 1996
- Lung bioavailability of generic and innovator salbutamol metered dose inhalers.Thorax, 1996
- In Vitro Properties of Pressurized Metered Dose Inhalers With and Without Spacer DevicesJournal of Aerosol Medicine, 1995
- Nebuliser performance, pharmacokinetics, airways and systemic effects of salbutamol given via a novel nebuliser delivery system ("Ventstream").Thorax, 1994
- Relative bioavailability of salbutamol to the lung following inhalation using metered dose inhalation methods and spacer devices.Thorax, 1994
- Comparison of three techniques of inhalation on the airway response to terbutaline.Thorax, 1983