Effect of Rotational Alignment On Patellar Tracking in Total Knee Arthroplasty
Authors:
- Yoshitaka MatsusueYMYoshitaka Matsusue
- Toshihiro MataTMToshihiro Mata
- Yoshiyuki AsadaYAYoshiyuki Asada
- Makoto HoriguchiMHMakoto Horiguchi
- Hirokazu IidaHIHirokazu Iida
- Takashi NakamuraTNTakashi Nakamura
- 1 September 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 366 (366) , 155-163
Abstract
Forty-four consecutive patients (65 knees) who underwent identical condylar type total knee arthroplasty were evaluated retrospectively. In 22 of the patients (32 knees), the femoral component was set parallel to the posterior condylar axis (neutrally aligned group). In the remaining 22 patients (33 knees), it was set in an external rotation position of 3° to 5° relative to the axis (externally aligned group). Of the total knee arthroplasties in the neutrally aligned group, 34% required lateral release, compared with only 6% in the externally aligned group; patellar tracking in the externally aligned group was significantly better than that in the neutrally aligned group. Postoperative measurements performed using computed tomography scans showed that the mean angle between the prosthetic posterior condylar axis and the transepicondylar axis was 7.9° in the neutrally aligned group and 3.2° in the externally aligned group. The external rotation setting of the femoral component diminished the need for lateral retinacular release and may decrease the rate of patellofemoral complications that occur after total knee arthroplasty.Keywords
This publication has 20 references indexed in Scilit:
- Femoral Condyle Geometry in the Normal and Varus KneeClinical Orthopaedics and Related Research, 1998
- Femoral Rotational Alignment Using the Tibial Shaft Axis in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Flexion space configuration in total knee arthroplastyThe Journal of Arthroplasty, 1995
- Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note.Journal of Bone and Joint Surgery, 1995
- Total knee arthroplasty with the kinematic condylar prosthesis. A ten-year follow-up study.Journal of Bone and Joint Surgery, 1995
- Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplastyThe Journal of Arthroplasty, 1992
- Blood supply to the patellaThe Journal of Arthroplasty, 1989
- Patellar fractures in total knee arthroplastyThe Journal of Arthroplasty, 1989
- The influence of tibial-patellofemoral location on function of the knee in patients with the posterior stabilized condylar knee prosthesis.Journal of Bone and Joint Surgery, 1986
- Patellar dislocation following total knee replacement.Journal of Bone and Joint Surgery, 1985